31 (70)
Instance Attributes (Instance #7 Ethernet Communication Settings 1)
Changes have immediate effect.
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Comm 1”
(Multilingual, see page
)
2
Data type
Get
UINT8
08h (= ENUM)
3
Number of elements
Get
UINT8
01h (one element)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
ENUM
Value
String
Meaning
(Multilingual, see page
)
00h
“Auto”
Auto negotiation (default)
01h
“10 HDX”
10Mbit, half duplex
02h
“10 FX”
10Mbit, full duplex
03h
“100HDX”
100Mbit, half duplex
04h
“100FX”
100Mbit, full duplex
6
Configured Value
Get
ENUM
Holds the configured value, which will be written to attribute #5
after the module has been reset.
Value
String
Meaning
(Multilingual, see page
)
00h
“Auto”
Auto negotiation (default)
01h
“10 HDX”
10Mbit, half duplex
02h
“10 FX”
10Mbit, full duplex
03h
“100HDX”
100Mbit, half duplex
04h
“100FX”
100Mbit, full duplex
Instance Attributes (Instance #8 Ethernet Communication Settings 2)
Changes have immediate effect.
#
Name
Access
Data Type
Description
1
Name
Get
Array of
CHAR
“Comm 2”
(Multilingual, see page
)
2
Data type
Get
UINT8
08h (= ENUM)
3
Number of elements
Get
UINT8
01h (one element)
4
Descriptor
Get
UINT8
07h (read/write/shared access)
5
Value
Get/Set
ENUM
Value
String
Meaning
(Multilingual, see page
)
00h
“Auto”
Auto negotiation (default)
01h
“10 HDX”
10Mbit, half duplex
02h
“10 FX”
10Mbit, full duplex
03h
“100HDX”
100Mbit, half duplex
04h
“100FX”
100Mbit, full duplex
6
Configured Value
Get
ENUM
Holds the configured value, which will be written to attribute #5
after the module has been reset.
Value
String
Meaning
(Multilingual, see page
)
00h
“Auto”
Auto negotiation (default)
01h
“10 HDX”
10Mbit, half duplex
02h
“10 FX”
10Mbit, full duplex
03h
“100HDX”
100Mbit, half duplex
04h
“100FX”
100Mbit, full duplex
Anybus
®
CompactCom
™
40 Modbus-TCP
®
Transparent Ethernet Network Guide
SCM-1202-022 1.1