43 (70)
Command Details: Process-modbus-message
Category
Extended
Details
Command Code:
10h
Valid for:
Object
Description
If enabled, this command routes Modbus/TCP communication to the host application.
•
Command Details
Field
Contents
Comments
CmdExt[0]
(reserved)
(ignore)
CmdExt[1]
MsgData[0... n]
Modbus message frame (Query)
-
•
Response Details
Field
Contents
Comments
CmdExt[0]
(reserved)
(set to zero)
CmdExt[1]
MsgData[0... n]
Modbus message frame (Response)
-
The response data size must not exceed 254 bytes, if more data is returned, no Modbus response message will
be sent to the originator of the request.
If the response contains no data, no Modbus response will be sent to the originator of the request.
Anybus
®
CompactCom
™
40 Modbus-TCP
®
Transparent Ethernet Network Guide
SCM-1202-022 1.1