25 (124)
5.7.2
PTP Setting
Fig. 8
PTP Setting
Configure the PTP settings:
Operation
Default: Disable
Enable or Disable the PTP function.
Operation must be enabled for the PTP function to work.
Operation Mode
Select Operation Mode from the drop-down menu, Auto Elect, Preferred Master Clock or
Slave.
Default: Auto Elect
Synchronization Interval Set the interval of the sync packet transmitted time.
A small interval causes higher load to the device and network.
Default: 0 (1s)
Announce Interval
Set the announce message interval.
Default: 1 (2s)
Announce Receipt
Timeout
The multiple of announce message receipt timeout by the announce message interval.
Default: 6
Minimum Path Delay
Request Message
Interval
Minimal delay request message interval
Default: 1 (2s)
Domain Number
Subdomain name (IEEE 1588-2002) or the domain Number (IEEE 1588-2008) fields in PTP
messages.
First Priority
Set the clock priority 1 (PTP version 2).
The lower values take precedence to be selected as the master clock in the best master clock
algorithm, 0 = highest priority, 255 = lowest priority.
Default: 128