Antti-Teollisuus Oy
9
408102
02-2020
Vacboost WM09
Dryer Heater
INSTALLATION
Safety instructions and regulations
The installation of the dryer heater must be carried out by a skilled electrician and a gas appliance fitter with relevant
authorisations, in the presence of a person, who is familiar with the installation procedure of the dryer machinery.
The permissions required for the building work and connecting the gas appliances need to be applied from, for
example, the gas supplier. Contact the local building authorities for additional information.
Selecting the installation location
The distance to the other buildings, and location of the debris pipe in the dryer, restrict the selection of the location.
The outlet air pipe must be located on the opposite side of the burner, and access of any debris or dust into the
suction net must be prevented.
Components to be installed in front of the gas burner
Depending on the requirements and conditions, either all or only part of the following components will be needed:
- pressure gauge before the pressure reducer
- gas meter
The electric and gas installations shall be exclusively assigned to persons with sufficient skills and valid authorisation.
The permissions required for the building work and connecting the gas appliances need to be obtained, for example,
from the gas supplier. Contact the local building authorities for additional information.
A diagram for connecting the actuators of the burner is delivered with the gas burner. The instructions for connect-
ing them to the control centre of the dryer are delivered with the centre.
Gas reservoir/connection
Consult the local municipal authorities for valid regulations for the gas reservoir and the gas connection. Turn to
the supplier of gas for more information.
NOTE! DEBRIS IN THE SUCTION AIR OF THE HEATER CONSTITUTES A FIRE HAZARD!
THE HEATER MUST BE LOCATED IN A PLACE WHERE ENTERING OF DEBRIS IS PREVENTED.
THE BURNER MUST BE PROTECTED AGAINST WATER. ANY DAMAGE, CAUSED BY WATER, IS NOT
COVERED BY THE GUARANTEE!