Antti-Teollisuus Oy
57
408116 03-2020
POSSIBLE MALFUNCTIONS
If the feeder stops and the signal light "Circulation failure" is illuminated
-
the fuse for the feeder motor has blown
-
the elevator has stopped
If the elevator stops, and the signal light "Circulation failure" is illuminated, (as a result of the above, the feeder
and the burner will stop in the automatic position).
-
see the malfunctions of the elevator in the Installation and Instruction Manual for the elevator.
Malfunctions in the burner:
- out of oil
-
light resistance cell sooty of blown
-
water in the oil filter or the filter is clogged
-
one of the shutter valves for the oil pipes is closed
-
thermo-relay for the motor has tripped
-
service switch for the oil burner is in position 0
-
no supply of air to the burner
-
refer to the Installation and Instruction Manuals for the dryer heater and the oil burner for more detailed mal
-
function tables
If the signal lights for the drying and the cooling phases in the automatic centre are illuminated simultaneously,
while the selector switch is in position MANUAL, and –when the switch is turned into position AUTOMATIC – the
burner stops, then turn the cooling timer to position 0. Reset the cooling time, and check that the temperature
setting of the digital thermostat is higher than the temperature inside the outlet channel. Press the Start button of
the dryer The drying process will commence normally.
Note! the elevator, the bottom screw and the feeder must be running.
SERVICE AND WINTER MAINTENANCE
Lubricate once a week
-
elevator bearings
-
feeder bearings
-
transmission arms of the feeder (2–3 drops of oil)
Annually
-
maintenance of the oil burner (assign a specialist)
-
checking the feeder motor gearbox (check oil leaks)
Содержание Plug&Dry
Страница 10: ...Antti Teollisuus Oy 10 408116 03 2020 ...
Страница 13: ...Antti Teollisuus Oy 13 408116 03 2020 yellow green red yellow black Unit specific cabling Cable ladder ...
Страница 18: ...Antti Teollisuus Oy 18 408116 03 2020 ...
Страница 22: ...Antti Teollisuus Oy 22 408116 03 2020 ...
Страница 30: ...Antti Teollisuus Oy 30 408116 03 2020 ...
Страница 32: ...Antti Teollisuus Oy 32 408116 03 2020 Dimensioning of the basic parts viewed from the side ...
Страница 34: ...Antti Teollisuus Oy 34 408116 03 2020 Principle dimensioning drawings for the 10 m and 17m intake pits ...