Feeder
To test run the feeder, first switch on the elevator and the bottom screw. Start the feeder. The feeder should
start. The direction of rotation of the feeder motor has no significance. If the feeder is equipped with a
frequency converter controlled rotation speed adjustment, check also its operation.
Blower
Start the blower. The blower should start. Check, and as required, change the direction of rotation of the
motor.
Burner
Only an authorised oil burner fitter is allowed to start up the burner. Before testing the oil burner, check that the
nozzles installed in it are the ones mentioned in the heater's manual. The maximum allowed oil flow, mentioned
in the heater's nameplate, must not be exceeded.
LTM thermostat
Start the blower and the burner in accordance with the instructions above. Allow the temperature to rise to
80 °C. Open the LTM thermostat's box. Turn the setting of the LTM thermostat's overheat protection lower
than the temperature of the inlet air. The burner shall now stop, and the blower shall continue to run. As
soon as the temperature of the inlet air drops below 45 °C, the burner shall restart. After having finished the test,
return the setting of the overheat protection to the value mentioned above.
Содержание Plug&Dry
Страница 10: ...Antti Teollisuus Oy 10 408116 03 2020 ...
Страница 13: ...Antti Teollisuus Oy 13 408116 03 2020 yellow green red yellow black Unit specific cabling Cable ladder ...
Страница 18: ...Antti Teollisuus Oy 18 408116 03 2020 ...
Страница 22: ...Antti Teollisuus Oy 22 408116 03 2020 ...
Страница 30: ...Antti Teollisuus Oy 30 408116 03 2020 ...
Страница 32: ...Antti Teollisuus Oy 32 408116 03 2020 Dimensioning of the basic parts viewed from the side ...
Страница 34: ...Antti Teollisuus Oy 34 408116 03 2020 Principle dimensioning drawings for the 10 m and 17m intake pits ...