ECONOMICAL DRYING
You must select the operating mode as a compromise between the output and the economy. Applying suitable
methods, you will be able to improve them both at the same time.
Thermal economy
The correct drying air temperature is the most important factor impacting on the efficiency and economy.
Remember the first main rule:
If the amount of air remains the same, raising the temperature will result in higher output and better economy.
As the temperature rises, the drying air's ability to absorb steam is multiplied, and the output increases abruptly.
Under normal air pressure, for example, the following amounts of steam correspond to relative humidity of 100 %.
at 0 °C
5
grams of water in m³ of air
at 20 °C
17
“”
at 30 °C
30
“”
at 50 °C
83
“”
at 60 °C
130
“”
at 70 °C
220
“”
at 75 °C
242
“”
Remember that the lower the relative humidity of the drying air, the
faster
water evaporates from the corns.
One m³ of the dryer heater's suction air at a temperature of +10 °C, and with relative humidity of 90 %, contains 8
g of water. When iy is heated to +70° C, it expands by about 50 %. This amount of air still contains the same 8 g
of water, corresponding to the relative humidity of 2.7 %. The air almost "sucks" moisture from the corn. Because
the relative humidity of the suction air is less significant, hot air drying is efficient and economical even when it
is raining.
Need to reduce the amount of air
You may have dimensioned your dryer and dryer heater following the standards, but you still may encounter situ
-
ations, where the maximum temperature allowed for the heater (maximum nozzle size) will not raise the drying air
temperature sufficiently. In this case, you need throttle the air flow as much as is necessary to make the temperature
of the drying air rise. This way you will be able to improve both the dryer's output and economy.
Содержание Plug&Dry
Страница 10: ...Antti Teollisuus Oy 10 408116 03 2020 ...
Страница 13: ...Antti Teollisuus Oy 13 408116 03 2020 yellow green red yellow black Unit specific cabling Cable ladder ...
Страница 18: ...Antti Teollisuus Oy 18 408116 03 2020 ...
Страница 22: ...Antti Teollisuus Oy 22 408116 03 2020 ...
Страница 30: ...Antti Teollisuus Oy 30 408116 03 2020 ...
Страница 32: ...Antti Teollisuus Oy 32 408116 03 2020 Dimensioning of the basic parts viewed from the side ...
Страница 34: ...Antti Teollisuus Oy 34 408116 03 2020 Principle dimensioning drawings for the 10 m and 17m intake pits ...