3

CAUTION!

Unplug mains lead before opening the housing!

FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY 

BEFORE YOU INITIAL START - UP!

1. Safety instructions

Every person involved with installation and maintenance of this product has to:

- be qualilfied

- follow the instructions of this manual

CAUTION!

 Be careful with your operations. With a high voltage  you can suffer

a dangerous electric shock when touching the wires inside the unit!

This product has left our premises in absolutely perfect condition. In order to maintain this condition and to 

ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning 

notes written in this manual.

To prevent from danger of accident ,the device has to be fixed on flat, non-f lam-

mable surface  in compliance with the installing instruction included in this manual.

 

Important:

The manufacturer will not accept liability for any resulting damages caused by the non-observance of this 

manual or any unauthorized modification to the product.

Always ground the unit.

The electric connection, repairs and servicing must be carried out by a qualified employee.

Do not connect this unit to a dimmer pack.

Use  a source of AC power that complies with local building and electrical rules.AC power has to have both 

overload and short circuit protection

2. Operating determinations

This product was designed for indoor use with  Luxeon K2 LED´s modules only.In case of connecting 

1W LED´s modules these modules will be destroyed! 

If the unit has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on 

immediately. The arising condensation water might damage your unit. Leave the unit switched off until it has 

reached room temperature.

Avoid brute force when installing or operating the unit.

When choosing the installation-spot, please make sure that the unit is not exposed to extreme heat, moisture 

or dust. 

Only operate the unit after having checked that the housing is firmly closed and all screws are tightly fas

-

tened.

The maximum ambient temperature 40° C must never be exceeded.

Operate the unit only after having familiarized with its functions. Do not permit operation by persons not quali-

fied for operating the unit. Most damages are the result of unprofessional operation!

Please use the original packaging if the product is to be transported.

Please consider that unauthorized modifications on the unit are forbidden due to safety reasons!

Содержание ArcPower 72/K2

Страница 1: ...version 1 7...

Страница 2: ...rating via DyNet protocol 9 6 ArcPower 72 K2 Control menu map 10 7 ArcPower 72 K2 DMX protocol 11 8 Control board 12 8 1 Addressing the ArcPower 72 K2 12 8 2 Program running 12 8 3 Manual mode 13 8 4...

Страница 3: ...fied employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to have both overload and short circuit protection...

Страница 4: ...re the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be 1 Control board 2 Power Indicator 3 DMX Output 4 DMX Input 5 LED Zone outputs 6 RS 232 Output 7 Fuse Hol...

Страница 5: ...ientation and fixed by the 4 screws There are 4 mounting holes of diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cable RJ4...

Страница 6: ...g from the mains before installation 2 Connect the LED modules to the fixture Make sure that all modules include Luxeon K2 LED s 3 Connect the DMX controller to the fixture 4 Connect the fixture to th...

Страница 7: ...n be chained together At the last ArcPower 72 K2 the data link has to be terminated with a terminator A termination plug is simply a RJ45 connector with a 120 resistor between pins Data and Data Plug...

Страница 8: ...ll slaves are connected Up to 32 fixtures can be connected in master slave chain 4 Insert the termination plug with 120 Ohm into DMX input of the master fixture and into the DMX output of the last sla...

Страница 9: ...l level Byte 3 80 Channel Byte 4 ff Channel Offset Byte 5 00 Fade Rate Byte 6 FF fixed value Byte 7 1C Checksum Area 0 to 255 as set on the Arcpower to give a unique address for each Arcpower unit i e...

Страница 10: ...0 255 MAn rE1 0 255 FA t 0 255 Gr1 0 255 S tI 0 255 bL1 0 255 COP MAC 0 255 Str 0 255 diM 0 255 tSt St A MSt E P 1 P06 SLA SPE VEr bAL On OFF C bA rE b 0 200 Gr b 0 255 bL b 0 215 Zon Z 00 Z 08 d MP M...

Страница 11: ...135 136 143 144 151 152 159 160 167 168 175 176 183 184 191 192 199 200 207 208 215 216 223 224 231 232 239 240 247 248 255 Macro selection No function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6...

Страница 12: ...the starting DMX address from which the ArcPower 72 K2 will respond to the DMX controller Setting the DMX start channel for DMX operating 1 Connect ArcPower 72 K2 to the mains 2 Browse through the men...

Страница 13: ...p select option COP and confirm it by pressing ENTER Both Fade time and Standing time use the same conversion table in order to convert DMX value to the time value DMX Time sec DMX Time min DMX Time m...

Страница 14: ...ion switch on both master and slave at a time or first slave s and after that master Running program has to be the same on all fixtures Note If the master runs its editable program EP1 EP2 or EP3 all...

Страница 15: ...rect values The menu items their name and order stated below match to a standard RGBW colour variant of LED modules connected to both LED inputs zones rE1 red LED s at zone 1 R rE2 red LED s at zone 2...

Страница 16: ...ture control panel SPE UPd yES From this option you cannot return back to the main menu If you do not want to continue in software update you have to switch off and on the fixture to leave this option...

Страница 17: ...main menu of the ArPower 72 K2 press ENTER use UP and DOWN buttons to select Zon The option enables to select desired number of the zone from 0 to 8 Press ENTER use UP and DOWN buttons to select zone...

Страница 18: ...means DMX value of the green colour 0 255 b means DMX value of the blue colour 0 255 means end of character sequence values of colours have to be separated by a comma Examples zone 0 234 126 165 zone...

Страница 19: ...e LED zone output and all its connected LED modules 20 metres at max load DMX channels Mode 1 6 channels Mode 2 8 channels Mode 3 11 channels Mode 4 4 channels Mode 5 4 channels Control and programmin...

Страница 20: ...45 DMX 5 pin No 13050731 11 Replacing the fuse 1 Before replacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 72 K2 with a fitting screwdriver from the housin...

Отзывы: