6
2.
RJ45 patch cables category 5 that connect the ArcPower 16x1 each other are wired 1:1,that is,pins with the
same numbers are connected together.
Pin 1:
Not used
Pin 1:
Not used
Pin 2:
Not used
Pin 2:
Not used
Pin 3:
Not used
Pin 3:
Not used
Pin 4:
Not used
Pin 4:
Not used
Pin 5:
+5V
Pin 5:
+5V
Pin 6:
Data +
Pin 6:
Data +
Pin 7:
Data -
Pin 7:
Data -
Pin 8:
GND
Pin 8:
GND
5 DMX operation
1.Unplug from the mains before installation.
2.Connect the LED modules to the fixture according to the operation (RGB or RGBW).
3.Connect DMX controller to the fixture
4.Connect the fixture to the mains
5.Set the DMX address on the control board of the fixture (see chapter "Control board").
Warning!
Accidental connection DMX 512 Input/Output to non-DMX 512 device (e.g.Ethernet
network Hub) can damage the ArcPower 16x12.
Maximum total cable length between Arcpower 16x12 and all connected LED modu-
les is 80 metres.
5.1 Single ArcPower 16x12 installation
1. RGB operation
2. RGBW operation
The ArcPower 16x1 allows to operate 1 RGBW outputs (zones) and it is not necessary to change its menu
setting.
Note: Only 12 zones of the ArcPower 16x12 can be used for RGBW operation - see chapter 3 "Descrip
-
tion of the ArcPower 16x12"
.
Max. load per LED output zone: 1x1W
LED
Number of zones: 16