1

Use [UP] and [DOWN] buttons  to select desired dimmer characteristic and press [ENTER] to confirm.

i.bLi.

 ---

 Initial blink

. If this function is on, the ArcPower 16x1 makes auto-calibration (LED modules, one by 

one, lit on 100% for short time,) after switching it on. During this action the ArcPower 16x12 finds out the load 

connected to its LED outputs and makes auto-calibration. If the LED modules will not be changed (still the 

same LED modules connected), after first auto-calibration you can set "i.bLi" at Off, as  autocalibration takes 

some time. In case, that some LED modules will be changed (even the same type) you should perform  auto-

calibration again. 

In. Po.

 - Use the menu to set all effects to the desired positions at which they will stay after switching the fixture 

on without DMX signal connected.

dF.SE. 

--- 

Default Settings

 .Select this option to reset all fixture personalities  to the default values. 

uPd.

 ---

 Software update

 - 

The menu item allows you to update software in the fixture via either serial or USB 

port of PC.

The following are required in order to update software:

- PC running Windows 5/8/000/XP or Linux

- DMX Software Uploader 

- Flash cable RS3/DMX No.1305064 (if you want to use a serial port of PC)

- Robe Universal Interface (if you want to use an USB port of PC)

Note1:

  Software update should execute a qualified person. If you lack qualification, do not attempt the update 

yourself and ask for help your ROBE distributor.

Note 2:

  DMX address, programs 1-2 and all items in the menu "SPEC" will be set to their default values.

To update software in the fixture:

I. Installation of the DMX Software Uploader.

 

1.   DMX Software Uploader program is available from the Anolis web site at WWW.anolis.cz.

 

.   Make a new directory ( e.g. Robe_Uploader) on your hard disk and download the software into it. 

 

3.   Unpack the program from the archive. 

II.Fixture software updating.

1. 

Determine which of your  port is available on your PC and connect it:

with the DMX input of the fixture if you using the flash cable RS232/DMX

with the DMX input of the Robe Universal Interface if you using the USB cable.   

Disconnect the fixture from the other fixtures in a DMX chain. Turn both the computer and the fixture on. Make 

sure the lamp is switched off (only if the fixture involves a lamp).

Switch the driver to the updating  mode:

Use the UP/DOWN buttons to find  “SPEC.“ menu.

 

Press the ENTER button.

Use the UP/DOWN buttons to select  “ uPd.“  item.

Press the ENTER  button

Use  the UP/DOWN buttons to select  “ yES“  option

Press the ENTER  button

 

Note:  If you do not want to continue in software update, you have to switch off and on the fixture

 

to escape from this menu.

 

3. We recommend to cancel all running programs before start of the Software Uploader.

 

4. Run the Software Uploader program. Select desired COM and then click on the Connect button.

Содержание ArcPower 16x12

Страница 1: ...Version 1 3...

Страница 2: ...operation 6 5 1 Single ArcPower 16x12 installation 6 5 2 Multiple ArcPower 16x12 installation 7 6 ArcPower 16x12 Control menu map 8 7 ArcPower 16x12 DMX protocol version 1 2 10 8 Control board 16 8 1...

Страница 3: ...airs and servicing must be carried out by a qualified employee Do not connect this unit to a dimmer pack Use a source of AC power that complies with local building and electrical rules AC power has to...

Страница 4: ...AC power source from 100 240 Volts Carefully prepare the end of the the supply cord and fit a suitable plug A 3 prong grounding type plug must be installed following the manufacturer s instructions Th...

Страница 5: ...are four mounting holes of a diameter 5 mm in housing of the driver Ensure that instalation place is enough ventilated 4 3 Conection cables 1 The adapter cable RJ45 XLR connects the ArcPower 16x12 to...

Страница 6: ...o the fixture 4 Connect the fixture to the mains 5 Set the DMX address on the control board of the fixture see chapter Control board Warning Accidental connection DMX 512 Input Output to non DMX 512 d...

Страница 7: ...rcPower 16x12 until all fixtures are connected In this way up to 32 fixtures can be chained together At the last ArcPower 16x12 the data link has to be terminated with a terminator A termination plug...

Страница 8: ...0 255 bLu 1 0 255 Stro 0 255 dimr 0 255 tESt St AL Auto OFF tESt EPG 1 EPG 2 PLAY tESt EPG1 EPG2 Edit EPG1 EPG2 St 01 St 60 rEd 1 0 255 dimr 0 255 F tim 0 255 S tim 0 255 COPY SPEC P End 1 64 dM Pr M...

Страница 9: ...CHAr EYE LinE i bLi On Off dFSE no YES uPd no YES...

Страница 10: ...00 proportional 2 2 11 11 0 255 Green LED 4 Green LED saturation control 0 100 proportional 3 3 12 12 0 255 Blue LED 4 Blue LED saturation control 0 100 proportional ZONE 5 1 1 13 13 0 255 Red LED 5 R...

Страница 11: ...35 0 255 Green LED 12 Green LED saturation control 0 100 proportional 3 3 36 36 0 255 Blue LED 12 Blue LED saturation control 0 100 proportional ZONE 13 1 1 37 37 0 255 Red LED 13 Red LED saturation c...

Страница 12: ...128 143 144 159 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter ope...

Страница 13: ...0 255 Blue LED 3 Blue LED saturation control 0 100 proportional 4 12 0 255 White LED 3 White LED saturation control 0 100 proportional ZONE 6 1 13 0 255 Red LED 4 Red LED saturation control 0 100 pro...

Страница 14: ...ue LED 9 Blue LED saturation control 0 100 proportional 4 36 0 255 White LED 9 White LED saturation control 0 100 proportional ZONE 14 1 37 0 255 Red LED 10 Red LED saturation control 0 100 proportion...

Страница 15: ...9 160 255 Shutter Strobe Shutter closed Shutter open Strobe effect from slow to fast Shutter open Opening pulses in sequences slow fast Closing pulses in sequences fast slow Shutter open step step pro...

Страница 16: ...ntil the display shows current addres A001 Confirm by pressing ENTER button and A001 will start to flash frequently 3 Use the UP and Down buttons to select the desired address 4 Confirm by pressing EN...

Страница 17: ...am No 1 EPG 2 program No 2 PLAY Playing program Select this menu to run a desired program immediately tESt The option starts test program EPG 1 The option starts editable program No 1 EPG 2 The option...

Страница 18: ...econds will receive Red 255 DMX It means that red will go to full intensity during 5 seconds Max fade time is reduced from 8 sec to 5 sec Note the value adjusted in the item M F ti will not influence...

Страница 19: ...qualified person If you lack qualification do not attempt the update yourself and ask for help your ROBE distributor Note 2 DMX address programs 1 2 and all items in the menu SPEC will be set to thei...

Страница 20: ...o update only later versions of processors check the Incremental Update box Avoid interrupting the process Update status is being displayed in the Info Box window When the update is finished the line...

Страница 21: ...on LED zones 12 Max load per zone 16 x 1W LED Total max load 12x16 LEDs Maximum total cable length between one zone of the Arcpower 16x12 and connected LED modules 80 metres at max load DMX channels M...

Страница 22: ...10 Replacing the fuse 1 Before replacing the fuse unplug mains lead 2 Unscrew the fuse holder on the rear side of the ArcPower 16x12 with a fitting screwdriver from the housing anti clockwise 3 Remove...

Страница 23: ...23...

Отзывы: