1.5 in
greater than 1.5 in
BULKHEAD
{ mounting surface }
1
2
3
4
AngelTrax
| 9
ATCF460 Hardware Installation
Plan the location for each piece of your mobile video surveillance system. It is important to mount the MDVR in a location providing
easy access to the front and rear of the device. This ensures you will be able to quickly and easily access the rear of the MDVR, where
all connections are made. You will always need access to the front of the MDVR to pull the CF card.
1. The bulkhead is the recommended location to mount the
DVR. The cables should be run to the bulkhead from their
source (i.e. power, signals, cameras, GPS antenna, etc.).
2. Drill a hole slightly to the left of the mounting location of the
ATCF460. The hole should be a diameter larger than the end
of your largest cable (approximately 1.5 inches - see
Figure 1). We recommend placing a rubber grommet around
the edges of this hole to prevent the cable being cut by
sliding across its sharp edges.
3. Run all cables, including power, signals, cameras, etc. to the
mounting location for the ATCF460. Pull the cables through
the hole drilled in step two (see Figure 2).
4. Using the screws provided, attach the DVR to the bulkhead
(see Figure 3).
5. Connect the power cable to the power source, then connect
the power cable and ignition to the MDVR (see Figure 4).
Power-up the MDVR by turning on the vehicle’s ignition.