- 8 -
3378750_GB_inst
ENGLISH
GB
ELECTRICAL CONNECTION
Caution - Warning
The connection must be made by authorised, skilled personnel, in accordance with the rel-
evant legal requirements, using appropriate and specifi ed materials.
The appliance is supplied with operating voltage 230V/1N 50 Hz (230V/1N 60 Hz available
on request)(see attached wiring diagrams).
Before doing any work, cut off the mains electricity supply.
Connect the appliance to the mains electricity supply
as follows.
1)
If not already present, install an automatic circuit-
breaker
(B)
, protecting only each single appliance
and located close to it, with the following character-
istics.
– Thermal breaker device (to adjust see table on page 3
of the user instructions manual)
– Diff erential breaker set at 30 mA
– Class B or C (IEC 898)
2)
Undo the screws and remove the side panel
(A)
.
3)
Connect the automatic circuit-breaker
(B)
to the
appliance’s terminal board
(C)
and to the electri-
cal mains supply, in accordance with the electrical
system diagram provided at the back of the manual
and using a cable with the following characteristics.
– Weight: ≥
than H05RN-F type (designation 245 IEC
57)
– Temperature of use: ≥70°C.
B
A
C
A
Important
When connecting, take care to connect the phase and neutral lines.
4)
Replace the panel and retighten the screws when the operation is complete.
GAS CONNECTION
Caution - Warning
Make the connection in compliance with the rel-
evant legal requirements, using appropriate and
recommended materials.
To make the connection, connect the mains line to
the appliance’s connection pipe, fi tting a shut-off tap
(A)
, to allow the gas supply to be cut off when neces-
sary.
Important
The tap (A), not supplied with the appliance, must
be installed in an easily accessible position and its
status (on or off ) must be obvious at a glance.