- 7 -
3220000_inst_GB
ENGLISH
GB
MOVIMENTAZIONE E SOLLEVAMENTO
The room where the appliance is installed must
have air inlets to ensure that the appliance can
operate correctly and provide the necessary air
exchange in the room itself.
The air inlets must be of appropriate size and
must be protected by gratings and placed so
that they cannot be obstructed.
ROOM VENTILATION
INSTALLATION OF THE APPLIANCE
All installation stages must be considered right
from production of the general layout. Before
starting these stages, as well as deciding the pla-
ce of installation, if necessary, the person authori-
sed to carry out these operations must organise a
“safety plan” to protect the people directly invol-
ved, and he must also ensure strict compliance
with all legal requirements, especially those rela-
ting to mobile work-sites.
The place of installation must have all the con-
nections needed to supply the appliance and
dispose of the production residues, must be
suitably lit and must meet all legal health and
hygiene requirements to prevent the contami-
nation of the foods.
If necessary, fi x the exact position of each indivi-
dual appliance or subassembly by mark coordi-
nates to locate them correctly (see explanatory
diagram).
100
mm
50 mm
Install at a distance of no less than 50 mm from
the rear wall and no less than 100 mm from the
side wall if they are not heat-resistant to tempera-
tures of at least 90°C.
Install in accordance with the relevant legislation,
regulations and specifi cations in the country of use.
The appliance can be handled using fork-lift or
hook equipment of suitable load-carrying ca-
pacity.
Before lifting, check the position of the load’s
centre of gravity.