C13960
4000.
fm
- 11 -
English
IT
GB
DE
FR
ES
The appliance has been tested before being put into
service. The information provided below is intended
to assist in the identification and correction of any
anomalies and malfunctions which might occur dur-
ing use. The user can solve some of these prob-
lems himself, but for others specific technical
knowledge or skill is required, and so they must only
be carried out by qualified staff with recognised ex-
perience acquired in the specific sector of operation.
FAULT
6
TROUBLESHOOTING
Fault
Causes
Remedies
The heating elements do not
come on.
Electrical connection not made
correctly.
Check the connection of the
electrical wires.
Safety thermostat tripped.
Carry out the appliance reset
(see page 15).
Switch faulty.
Replace the switch.
The appliance does
not heat up.
Check the thermostat and activate
any start-up enabling device.
Contactor not receiving power or
faulty.
Check or replace the contactor
coil.
Electronic circuit board
does not switch on.
Electrical connection error.
Check or swap the phase
wire connections.
TABLE OF ALARM INDICATIONS
Alarm
Cause
Remedy
EO
Sensor has short-circuited;
electrical connection faulty.
Important
Contact the after-sales
service.
EOC
Electronic control device faulty.
Important
Contact the after-sales
service
E2
Loss of data set on the electronic
circuit board.
Switch the appliance off and
back on;
Important
if the problem persists, call
the after-sales service
AL1
The maximum permitted
temperature values have been
exceeded; break in sensor
circuit.
Wait for the oil to cool down;
Important
if the problem persists, call
the after-sales service.