Important
This adjustment is only required if the type
of gas to be connected is different from that
used for testing after the conversion proce-
dure has been carried out (see page 18). Be-
fore making this adjustment, check that the
gas supply pressure is the same as the rat-
ed pressure for the type of gas in use (see
table at back of manual).
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob
(A)
.
3 - Undo the scr ews
(C)
and remo ve the control
panel
(B)
.
4 - Remove the injector
(D)
and replace it with the
one suitable for the type of gas in use (see table
at back of manual).
5 - Fully screw the injector.
6 - After making the setting, se al the screw
with paint.
7 - Replace the control panel
(B)
and the
knob
(A)
on completion of the operation.
ADJUSTING GAS CONTROL VALVE MINIMUM SETTING
To carry out this operation, proceed as follows.
1 - Turn off the gas supply tap.
2 - Pull off the knob
(A)
.
3 - Undo the scr ews
(C)
and remo ve the control
panel
(B)
.
4 - Undo the locking screw
(D)
.
5 - Set the bush
(E)
in contact at the distance
shown in the figure.
6 - Tighten the screw
(D)
.
7 - After making th e setting, seal the screw with
paint.
8 - Replace the control panel
(B)
and the knob
(A)
on completion of the operation.
ADJUSTING BURNER PRIMARY AIR (190BM2G)
A
IDM-39615801500.tif
C
D
B
C
A
IDM-39615801600.tif
C
D
B
C
E
3711 mm
2811
mm
C139615800_1.fm Page 20 Monday, December 20, 2010 3:36 PM