6.5
Removing the hydraulic motor
-
Use the air regulator to move the limit switch rod
(A) to the opposite side relative to that to be
removed (then release the air and disconnect the
supply pipes as described in paragraph 6.4).
-
Remove the delivery pipe assembly (1) by
unscrewing the nuts (2a) and (2b). When
removing the nut (2b), tighten the nut (2c) with a
second wrench by pushing counterclockwise.
-
Totally unscrew the screws (43) and remove the
limit switch cover plate (44) as well as the pneu-
matic limit switch (42).
-
Remove the suction pipe assembly (7) by
unscrewing the nuts (6).
I
MPORTANT:
To remove the delivery pipe assembly (1) and the suction pipe assembly (7), please read paragraph
6.9 and 6.10.
-
Unscrew the screws (34) and pull out the pum-
ping hub (32) as well as the takeup hub (28); it is
now possible to pull out the lip seal (31) and
replace it.
-
Unscrew the piston fastening screw (18) and by
using a puller, pull the piston (16) out of the
chromium plated shaft (4).
-
Pull out the bellows flange (26).
-
Pull the bellows (14) out of the chromium plated
shaft (4) by forcing it out with your hand.
WARNING:
-
Do not scratch or dent the surface of the piston during disassembly.
-
It is recommended to remove the bellows only if it must be replaced.
25
Содержание MSU B193
Страница 35: ...35 FIGURE 1...
Страница 37: ...37 EXPLODED VIEW MOTOR BM25046...
Страница 39: ...39 EXPLODED VIEW MOTOR BM20046...
Страница 47: ...47 NOTE...