
13
5.1
CONDITION FOR INSTALLATION
• The installer must know the ATEX classification of the installation area, as well as the risks coming
from a potentially explosive atmosphere, by paying attention to the explosion and fire risks so as to
adopt the most suitable protections.
• All maintenance, assembly and disassembly operations must be carried out by a qualified staff
outside the area at risk of explosion.
• Also check that the accessories comply with the essential safety requirements of the ATEX direc-
tives. Handle them with great care to avoid changing their features.
• Once installed, clean the unit.
• Use antistatic hoses for connection of Multi Spray Unit and spray gun.
The equipment must be installed by a
specialized and authorized staff.
In any case, follow the instructions below.
Painting
must preferably take place inside a suitable spray booth equipped with suction device.
Do not use the unit if the suction device is off.
WARNING
IF PAINTING IS CARRIED OUT OUTSIDE THE SPRAY BOOTH, ALWAYS OPERATE IN A PLACE
WITH A RIGHT VENTILATION TO AVOID CONCENTRATING INFLAMMABLE VAPOURS COMING
FROM SOLVENTS OR PAINTS.
5.2
INSTALLATION
- Place the equipment on the floor, on a horizontal surface.
- Secure it firmly to the ground by means of the trolley fastening bracket (pic.2 on page 14).
- Connect the dip tube steadily (pos. A in pic. 2 on page 14) and the recirculation hose (pos. B in pic. 2
on page 14).
- Connect the twin hose for air and paint, to air regulator and to delivery paint filter.
- Earth the free end of the ground cable directly.
- Connect the Multi Spray gun to the other end of the air/paint twin hose.
- Connect the air supply hose to the unit.
WARNING
- CHECK THE PROPER TIGHTENING OF ALL FITTINGS, SINCE THEIR SUDDEN OPENING CAN
SERIOUSLY INJURE PEOPLE.
WARNING
- CONSULT THE LOCAL CODE FOR DETAILED INSTRUCTIONS RELATIVE TO GROUND CON-
NECTIONS IN THE WORK AREA AND TO THE TYPE OF SYSTEM USED.
- THE GROUND CABLE (INCLUDED IN THE SUPPLY) MUST HAVE A MINIMUM SECTION
EQUAL TO 1.5 mm
2
.
- ONE END OF THE CABLE MUST BE EARTHEN WHILE THE OTHER MUST BE CONNECTED
TO THE LID OF THE PNEUMATIC MOTOR SILENCER.
5. INSTALLATION AND STARTING
Содержание MSU-323 C
Страница 25: ...25 8 2 EXPLODED VIEW...