4. Setup
4-3. Checking operation
WARNING
1. Never touch moving parts.
IMPORTANT
1. Do not keep pump idling for extended periods of time. Prolonged idle operation may cause premature
pump failure.
Refer to
Fig.1
on page 8 or
Fig.2
on page 9 to find reference letters.
1. Check
Fluid Filter Set
(I) if installed, suction filter installed on
Suction Hose Set
(E) and filter set installed on
spray gun. If they are clogged, clean or replace.
2. Close
Air Regulators
(C and F) fully.
3. Open
Circulation Valve
(G).
4. Set
Emergency Valve
(D) to “
Operating
” position.
5. Turn on the air supply to the unit.
6. Remove
Suction Hose Set
(E) from the pump fluid inlet and adjust
Air Regulator
(C) to 22 - 73psi (0.15 -
0.5MPa, 1.5 - 5bar) slowly.
7. After pump is running, cover fluid inlet fitting underneath the pump with your palm and feel for suction to make
sure that pump is working. If not, see
8. Trouble Shooting
on page 16.
8. Set
Emergency Valve
(D) to “
Emergency Stop
” position to make sure that pump operation stops.
9. Close
Air Regulators
(C and F) fully.
10. Connect
Suction Hose Set
(E) and
Circulation Tube
(H). If they are clogged or damaged, clean or replace.