- 14 -
Ű
6. Cleaning
WARNING
1. Use in well-ventilated spray booth.
2. Avoid any ignition sources such as smoking, open flames or electrical hazard.
3. Always wear protective clothing, eyewear, gloves and respirator.
4. Never spray toward a person or animals and never pull the trigger of the spray gun
near the body.
5. Never stop or deflect a fluid leak from the spray equipment or fluid hose with your
hand. Be sure to stop the spray equipment according to
5-4. Emergency stopping
procedure on page 13.
CAUTION
1. Be sure to use compatible cleaning fluid with the wetted parts of this unit.
IMPORTANT
1. Flush fluid passage of this unit completely with cleaning fluid every time after use. If not, it can cause finish
problem and pump malfunction.
2. Always fully close or fully open the circulation valve. Opening the valve halfway can cause seat wear, fluid
leakage and lack of fluid pressure.
3. Be sure to follow local guidelines for proper cleaning and fluid disposal procedures.
HINT
1. Position plunger pump at the end of down stroke to increase pump life when not in use.
Refer to
Fig.1
on page 8 or
Fig.2
on page 9 to find reference letters.
1. Remove nozzle tip from spray gun.
2. Clean fluid passage of pump and spray gun. Refer to
5-1. Flushing
procedure on page 12.
3. Place nozzle tip to spray gun and spray cleaning fluid through nozzle tip to clean inside of nozzle tip.
4. Clean
Fluid Filter Set
(I, if installed), suction filter installed on
Suction Hose Set
(E) and filter set installed on
spray gun. Replace if necessary.