4. Setup
4-1. Wall mount unit installation
CAUTION
1. Be careful not to drop this unit during installation.
2. Install this unit on stable wall able to support the weight of this unit, hoses, any accessories and material
inside the pump and stress created by pump operation.
Wall mount hole layout
Four 9mm (0.354in.) dia. holes
210mm (8.27in)
160mm (6.3in)
25mm (0.98in)
30mm (1
.18in)
35mm (1
.38in)
8
0
mm (3.
15in)
4-2. Setup
WARNING
1. This unit should be operated by adequately trained operators only.
2. To reduce the risk of static sparking, grounding continuity to the spray equipment, fluid container
and object being sprayed must be maintained.
3. Be sure to tighten all connections.
4. Be sure to follow fire prevention, electrical and other local regulations.
IMPORTANT
1. Install this unit in a dry, clean and well-ventilated area.
2. Use clean air filtered through a dryer and a filter finer than 50 microns. If not, it can cause spray equipment
malfunction and finish problem.
HINT
1. Grounded air hose designed by ANEST IWATA is available.
Refer to
Fig.1
on page 8 or
Fig.2
on page 9 to find reference letters.
1. Place this unit on hard level surface and load uniformly, if stand or cart mount unit.
2. Secure ground wire.
3. Close
Air Regulators
(C and F) fully.
4. Set
Emergency Valve
(D) to “
Emergency Stop
” position and open
Circulation Valve
(G).
5. Connect fluid and air hoses to the outlet fittings of this unit and other end to inlet fittings on spray gun. If hoses
or fittings are damaged, replace immediately.
6. Connect air supply hose to inlet of unit.