4
5
7. CHECKING OF THE PRODUCT
WHEN RECEIVING THE SPRAY GUN, MAKE SURE THAT IT HAS NOT BEEN DAMAGED DURING TRANSPORT
OR STORAGE AND ALSO CHECK THAT ALL THE FOLLOWING CONTENTS ARE INSIDE THE BOX.
STANDARD SPRAY GUN_Set includes:
Allen wrench
Brush
Universal spanner
Twisted brush
Ø10 mm
Instruction manual
6. TECHNICAL DATA
MODEL
Nozzle
Orifice
(mm)
Air cap set
Mark
Atomizing
air pressure*
bar (PSI/Mpa)
Air pressure
inside air cap
bar (PSI/Mpa)
Air
Consumption
l/min (cfm)
Fluid
output
ml/min
Pattern
width**
mm (in)
WS-400 BASE
WS-400-OBS.0
OBS-0
WS-400-02-OBS
2.0
(29 / 0.20)
-
370
(13.1)
210
255 (10.0)
WS-400-OBS
OBS
215
255 (10.0)
WS-400-OBS.1
OBS+1
235
260 (10.2)
WS-400-BFS
BF-S
WS-400-03-BF
245
250 (9.8)
WS-400 CLEAR
WS-400-12H03
12 HD
WS-400-03
2.0
(29 / 0.20)
-
370
(13.1)
220
245 (9.6)
WS-400-13H03
13 HD
245
250 (9.8)
WS-400-14H03
14 HD
260
255 (10.0)
WS-400-15H03
15 HD
280
260 (10.2)
LS-400 ET
LS-400-1206
12 ET
LS-400-06
1.8
(26 / 0.18)
0.7
(10 / 0.07)
400
(14.1)
165
230 (9.1)
LS-400-1306
13 ET
175
235 (9.3)
LS-400-1406
14 ET
185
240 (9.4)
LS-400-1506
15 ET
190
245 (9.6)
LS-400 ETS
LS-400-12S06
12 ETS
LS-400-06
1.8
(26 / 0.18)
0.7
(10 / 0.07)
420
(14.8)
160
200 (7.9)
LS-400-13S06
13 ETS
170
205 (8.1)
LS-400-14S06
14 ETS
185
210 (8.3)
LS-400-15S06
15 ETS
195
215 (8.5)
*Atomizing air pressure means air pressure at spray gun inlet when trigger is pulled and air flows
**Spray distance at 150mm
DIGITAL VERSION with Digital Pressure Gauge DPG-1_Set includes:
Allen wrench
Screwdriver
Brush
Coin battery 3 volt
Universal spanner
Twisted brush
Ø10 mm
Trigger Locking
Clip & Pin Cap
IMPORTANT: In order to proceed in the
correct way with the installation or the
replacement of the battery it is important to
strictly follow the instructions as showed on
SECTION 13.
Instruction manual
8. SAFETY WARNING
WARNING
FIRE AND EXPLOSION HAZARDS
SPARKS AND OPEN FLAMES ARE STRICTLY PROHIBITED
Paints can be highly flammable and can cause fire.
Do not expose to open flames, electrical goods, cigarettes etc.
SECURELY GROUND SPRAY GUN BY USING A CONDUCTIVE AIR HOSE. ELECTRICAL
RESISTENCE: <1MΩ. - ALWAYS ensure that the spray gun is earthed correctly.
Insufficient grounding can cause fire and explosion due to static electric sparking.
NEVER USE THE FOLLOWING HALOGENATED HYDROCARBON SOLVENTS which can cause
cracks or dissolution on gun body (aluminium) by chemical reaction. UNSUITABLE SOLVENTS:
methyl chloride, dichloromethane, 1.2-dichloroethane, carbon tetrachloride, trichloroethylene,
1.1.1-trichloroethane. BE SURE THAT ALL FLUIDS AND SOLVENTS ARE COMPATIBLE WITH
GUN PARTS.
WARNING
PROTECTION OF HUMAN BODY
USE IN A WELL-VENTILATED SITE BY USING A SPRAY BOOTH.
If not, poor ventilation can cause organic solvent poisoning and catch fire. If you feel any abnormality
during operation, consult a medical doctor immediately.
ALWAYS WEAR PROTECTIVE GEAR (safety glasses, mask, gloves.)
If not, cleaning liquid, etc., can cause inflammation of eyes and skin.
In case of any physical discomfort for skin or eyes, immediately seek a medical advice.
The noise level of ANEST IWATA Spray Gun doesn’t exceed the 85 dB (A) A-weighted sound
pressure value about the risk of daily exposure to noise. THE USE OF INDIVIDUAL HEARING
PROTECTION IS ALWAYS RECOMMENDED, because the terms of use and the influence of other
noises in the job area, could increase the average value allowed.
Pulling trigger many times during operation, may cause carpal tunnel syndrome.
ALWAYS REST, IN CASE OF TIREDNESS.
WARNING
IMPROPER USE OF THE EQUIPMENT
NEVER EXCEED MAXIMUM OPERATING PRESSURE AND MAXIMUM OPERATING TEMPERATURE.
Use at more than max. operating pressure can cause explosion of Spray Gun resulting in great danger.
ALWAYS RELEASE AIR AND FLUID PRESSURE BEFORE CLEANING, DISASSEMBLING OR
SERVICING. Otherwise, remaining pressure can cause bodily injury due to improper operation or
scattering cleaning liquid.
NEVER POINT SPRAY GUN TOWARDS PEOPLE OR ANIMALS.
TIP OF FLUID NEEDLE SET HAS A SHARP POINT.
Do not touch the tip during maintenance to avoid accidents.
NEVER USE THIS GUN TO SPRAY FOODS, CHEMICALS, CORROSIVE AND/OR ABRASIVE
PRODUCTS, otherwise the blend of foreign substances could cause corrosion of the fluid pas-
sages, which could adversely affect health.
ALWAYS DISASSEMBLE DIGITAL PRESSURE GAUGE MODULE FROM SPRAY GUN HANDLE
BEFORE CLEANING OR SERVICING.
NEVER ALTER THIS SPRAY GUN OR THE DIGITAL PRESSURE GAUGE MODULE DPG-1.
If done, it can cause insufficient performance and failure or in extreme cases, explosions.
EN
EN
WS-400
Series
2
[BASE & CLEAR]
- LS-400
Series
2
GRAVITY SPRAY GUNS
WS-400
Series
2
[BASE & CLEAR]
- LS-400
Series
2
GRAVITY SPRAY GUNS
WARNING
OTHER PRECAUTIONS
IF SOMETHING GOES WRONG, IMMEDIATELY STOP OPERATION AND FIND THE CAUSE
OF FAILURE. Do not use again until you have solved the problem.
NEVER DISASSEMBLE, MODIFY OR ATTEMPT TO REPAIR THE DIGITAL PRESSURE MODULE
DPG-1. In case of failure or malfunction, contact exclusively your ANEST IWATA Customer
Technical Service.