-2-
For safe operation
Below is very important information about how to safely operate the equipment.
Before operation, be sure to read and fully understand the contents.
WARNING
Be careful about
hoisting
Danger of cargo collapse
Be careful to install vacuum pump using
motor eyebolt and crane with sufficient
allowable load capacity (ISP-1000 mass
56kgs) while paying attention to stability of
suspended load. If not, it can cause
damage, failure or bodily injury from falling
cargo due to hoisting failure, or by being
caught between suspended cargo and
other material.
Avoid moisture
Danger of electric shock
Install in an area which is not exposed to
moisture such as rain or steam. If moisture
comes into and tact with the electric
source connection, it can cause fire or
bodily injury due to short-circuit or electric
shock.
Install at a safe
site
Danger of explosion, fire and
accident
Install in an area free from explosive,
flammable or corrosive substances.
If not, it can cause explosion, fire or
accident.
Ask qualified
electrician
Danger of short-circuit and
electric shock
Ask a qualified electrician to perform
electric wiring.
If not, short-circuit or electric shock can
cause fire or bodily injury.
Turn off electric
source
Danger of electric shock and
entanglement
Be sure to turn off electric source on
building site before wiring. If not, it can
cause electric shock or bodily injury due to
turning objects.
Install
overcurrent
protective device
Danger of accident, fire and
failure
Be sure to install protective device to
protect circuitry.
We recommend overcurrent protective
device (rated 15A) to protect branch
circuit.
If equipment is not stopped in an
emergency, it can cause accident, fire or
failure.
Install
emergency stop
switch
Danger of accident, fire or failure
Be sure to install an electric source
emergency stop switch (or protective
device that can urgently stop).
If equipment is not stopped in an
emergency, it can cause accident, fire or
failure.
Install short
circuit protective
device
Danger of fire and electric shock
Install short circuit protective device.
If not, it can cause bodily injury due to fire
or electric shock.
Install motor
protective circuit
breaker to
protect motor
Danger of electric fire and electric
shock
Install motor protective circuit breaker to
protect motor.
If not, it can cause bodily injury due to
electric fire or electric shock.
If you have any questions about the
selection of protective devices, contact
either the dealer who sold it to you or us.
Be careful about
wiring
Danger of short-circuit and
electric shock
We recommend an electric source cable
of more than 2mm
2
(more than rated 15A)
cross section area for electric source
cable and ground cable. Be careful to
avoid voltage drop considering local
situation. If not, it can cause a short-circuit
fire and may result in bodily injury from
electric shock.
Содержание ISP-1000
Страница 2: ......