-14-
Terminal plate
Terminal Block
Electric Source
Terminal M4 Nut
Ground Terminal
M5 Bolt
200V Connection
(When delivered to you)
400V Connection
Chart
-
1
Voltage
V
Frequency
Hz
Recommended protective
device (or breaker)
capacity
A
200
50
6.3
200
60
6.7
208
60
6.7
230
60
6.6
380
50
3.6
400
50
3.9
415
50
4.1
460
60
3.8
How to wire
①
Remove 4pcs. of M5 bolt at motor terminal box and remove protection cover.
※
Be careful not to lose removed M5 bolts and washer.
②
Wiring diagram is shown inside protection cover.
You can change to a 200V or 400V connection by changing terminal plate (3pcs.).
※
※
※
※
It is wired to 200V when delivered to you.
③
If you want to change to a 400V connection, remove M4 nut of electric source
terminal and change terminal plate as illustrated below.
④
Insert electric source cord through cable gland on the bottom side of terminal box.
⑤
Connect each phase L1-L2-L3 to each electric source terminal respectively in
accordance with the below wiring diagram.