background image

Template  version:1 

12/17 

MAINTENANCE 

 

1. 

 

Do not drop this monitor or subject it to strong impact. 

2. 

 

Avoid high temperature and solarization. Do not immerse the monitor in water as this 

will result in damage to the monitor. 

3. 

If  this  monitor  is  stored  near  freezing,  allow  it  to  acclimate  to  room  temperature  before 

use. 

4. 

 

Do not attempt to disassemble this monitor. 

5. 

If you do not use the monitor for a long time, please remove the batteries. 

6. 

It  is  recommended  the  performance  should  be  checked  every  2  years  or  after  repair. 

Please contact the service center. 

7. 

Clean the monitor with a dry, soft cloth or a soft cloth squeezed well after moistened with 

water, diluted disinfectant alcohol, or diluted detergent. 

8. 

No  component  can  be  maintained  by  user  in  the  monitor.  The  circuit  diagrams, 

component part lists, descriptions, calibration instructions, or other information which will 

assist  the  user

’s  appropriately  qualified  technical  personnel  to  repair  those  parts  of 

equipment which are designated repairably can be supplied. 

9. 

The  monitor  can  maintain  the  safety  and  performance  characteristics  for  a  minimum  of 

10,000  measurements  or  three  years,  and  the  cuff  integrity  is  maintained  after  1,000 

open

–close cycles of the closure.. 

10.  It  is  recommended  the  cuff  should  be  disinfected  2  times  every  week  if  needed  (For 

example, in hospital or in clinique). Wipe the inner side (the side contacts skin) of the cuff 

by a soft cloth squeezed after moistened with Ethyl alcohol (75-90%), then dry the cuff by 

airing. 

 

EXPLANATION OF SYMBOLS ON UNIT 

 

  Symbol for

” THE OPERATION GUIDE MUST BE READ”(The sign background colour: 

blue.The sign graphical symbol: white)   

   

Symbol for 

“WARNING” 

      Symbol for 

“TYPE BF APPLIED PARTS” (The cuff is type BF applied part) 

    Symbol for 

“ENVIRONMENT PROTECTION – Waste electrical products should not be 

disposed of with household waste. Please recycle where facilities exist. Check with your local 

Authority or retailer for recycling advice

”. 

 

Symbol for “MANUFACTURER” 

 

Symbol for 

“COMPILES WITH MDD93/42/EEC REQUIREMENTS” 

 

                 

Symbol for 

“DATE OF MANUFACTURE”

 

Содержание KD-723

Страница 1: ...OCEDURES 5 1 DOWNLOAD THE FREE APP 5 2 BATTERY LOADING 5 3 CLOCK AND DATE ADJUSTMENT 5 4 CONNECTING THE CUFF TO THE MONITOR 6 5 APPLYING THE CUFF 7 6 BODY POSTURE DURING MEASUREMENT 7 7 TAKING YOUR BL...

Страница 2: ...usually appears in the daytime and lowest one usually at midnight Typically the value begins to increase at around 3 00AM and reaches to highest level in the daytime while most people are awake and ac...

Страница 3: ...ored in the memory with date and time stamp The voice function will ease the operation The Electronic Sphygmomanometers corresponds to the below standards IEC 60601 1 2005 corr 1 2006 corr 2 2007 EN 6...

Страница 4: ...0 4 122 15 Environmental humidity for storage and transport 85 RH 16 Environmental pressure 80kPa 105kPa 17 Battery life Approx 170 times 18 Wireless Connection Smart Bluetooth Frequency Band 2 400 2...

Страница 5: ...formation regarding potential electromagnetic or other interference between the blood pressure monitor and other devices together with advice regarding avoidance of such interference please see part E...

Страница 6: ...f according to local regulations at the end of their usage 3 CLOCK AND DATE ADJUSTMENT a At first the Blood Pressure Monitor is totally off once you insert the battery the Blood Pressure Monitor will...

Страница 7: ...or by pressing START STOP button when the minute is blinking then the time and date is confirmed Note 3 1 The clock format could be set by user 4 CONNECTING THE CUFF TO THE MONITOR The cuff is attache...

Страница 8: ...o not move your arm body or the monitor during measurement Stay still calm for 5 minutes before blood pressure measurement Please keep the cuff clean Clean the cuff by wet soft cloth and mild detergen...

Страница 9: ...ly inflated The blood pressure and pulse will be measured during inflation Inflation will stop as soon as the blood pressure and pulse rate have been calculated and displayed on the LCD The irregular...

Страница 10: ...Press MEM button again to review the next result See picture 8 6 In this way repeatedly pressing the MEM button displays the respective results measured previously Picture 8 5 Picture 8 6 e When disp...

Страница 11: ...e different levels of blood pressure 12 TECHNICAL ALARM DESCRIPTION The monitor will show HI or Lo as technical alarm on LCD with no delay if the determined blood pressure systolic or diastolic is out...

Страница 12: ...to detect diastolic pressure LCD shows Er 3 Pneumatic system blocked or cuff is too tight during inflation Apply the cuff correctly and try again LCD shows Er 4 Pneumatic system leakage or cuff is to...

Страница 13: ...chnical personnel to repair those parts of equipment which are designated repairably can be supplied 9 The monitor can maintain the safety and performance characteristics for a minimum of 10 000 measu...

Страница 14: ...ANT INFORMATION REQUIRED BY THE R TTE This product is approved in accordance to R TTE directive transmitter interference This product complies with Industry Canada IC RSS 247 The Bluetooth word mark a...

Страница 15: ...e KD 723 is intended for use in the electromagnetic environment specified below The customer or the user of the KD 723 should assure that it is used in such an environment IMMUNITY test IEC 60601test...

Страница 16: ...NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from struct...

Страница 17: ...aximum output power of the communications equipment Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz...

Страница 18: ...rgy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particu...

Отзывы: