26
Problem
: No movement of a part of the automated functions of the RBMPro in automatic
pick up mode and/or in manual mode
Diagnosis: If you have already tested the manual lever (by putting the machine in Manual
function on the Danfoss control and then going to the levers on the side of the trailer)
and the function does move then you have a problem with the main valve
solenoid
.
You can verify the
solenoid by putting a
voltmeter on the pins
of the connector and
pushing the manual
function on the
Danfoss controller. If
there is no voltage at
the connector you may
have a wire problem.
Otherwise try replacing
the solenoid
PROCEDURE REF# A-RBM-007
Security Valve, Pressure reducer valve and Solenoid diagnosis