20
Hydraulic coupling
Product model
Number of
hydraulic outlet
required
Hydraulic function
North American coupling
description
European coupling referencial
RBMPRO2000
factory
configuration
(
Load sensing
)
1
Main valve
pressure line
3/4" male
FASTER: ANV-34-NPT-M
Main valve return
to the tank
3/4" female
FASTER: ANV-34-NPT-F
2
Load sensing
3/8" male
FASTER: ANV-38-NPT-M
3
Tilting unloading
platform
1/2" male
FASTER: 2NV-1/2-M
Tilting unloading
platform
1/2" male
FASTER: 2NV-1/2-M
Below configuration are necessary if the tractor pump is NOT load sensing (LS). However, when it is possible it is preferable
to run them with a load sensing tractor for lower oil temperature, and lower restriction when operating more than one
function. The RBMPRO2000 body valve can take up to 20 GPM (80L/min) but we recommend to adjust the flow at 14 GPM
(55L/min). The pressure requested will be in the range of 2900 PSI (200/210 BAR).
NEVER CONNECT THE RBMPRO2000 TO AN OLD TRACTOR NOT EQUIPPED WITH A VARIABLE
DISPLACEMENT PUMP
RBMPRO2000
(
If tractor has no
load sensing
)
1
Main valve
pressure line
Remove the 3/4" male coupler and the adaptor/reducer 3/4" to
1/2" and replace them by a 1/2" male coupler or European
reference part number is FASTER: 2NV-1/2-M
Main valve return
to the tank
Remove the 3/4" male coupler and replace by an
expander/adaptor 3/4" to 1/2" (BRENNAN: 5405-08-12 or
PARKER: 3/4-X1/2 FG-S) and then mount an 1/2" male coupler
or European reference FASTER: 2NV-1/2-M
2
Load sensing
No modification needed. The hydraulic hose dedicated to load
sensing can be stored and attached on the trailer .
3
Tilting unloading
platform
1/2" male
FASTER: 2NV-1/2-M
Tilting unloading
platform
1/2" male
FASTER: 2NV-1/2-M
PROCEDURE REF# A-RBM-003 (continued)
Connecting to the tractor (hydraulic) coupling chart
Содержание RBMPRO
Страница 18: ...18 PROCEDURE REF A RBM 001 hydraulic diagram...
Страница 33: ...33...
Страница 35: ...35 Arm s top view from the outside PROCEDURE REF A RBM 020 Wrist...
Страница 38: ...38 Back of the trailer Stopper rollers PROCEDURE REF A RBM 023 Stopper rollers...
Страница 43: ...43 PROCEDURE REF A RBM 014 Danfoss controller Home Screen...
Страница 44: ...PROCEDURE REF A RBM 015 Danfoss controller Reset bales loaded Adjust with touch screen...
Страница 45: ...45 PROCEDURE REF A RBM 027 Fuse location...