Error “PT_LS”
appearing on
screen
Bale carrier
Diagnostic procedure
“PT_LS” sensor located underneath the frame of the machine is an
hydraulic pressure reader sensor. It provide information to the
computer about the internal hydraulic pressure.
Some hydraulic movement of the RBMPRO are free of proximity
sensor in order to read if the arm ias
completed it’s movement.
Without proximity sensor to read the position, we therefore use the
internal pressure to provide back to the computer the information if
the cylinder as completed it’s cycle or not.
For example, when we open the loading arm grabber, as there is no
proximity sensor, the computer will engage the corresponding valve
section till the pressure reach 2500 PSI as per the factory setting,
which can be modified through the Danfoss touchscreen controller.
If you received the “PT_LS” error, it mean the RBMPRO could not built
the internal pressure high enough to meet the condition request by
the computer.