AD-4406 Weighing Indicator
Page
21
6. Functions
There are two parameter lists, one for the F-functions and one for CF-functions.
These functions control the indicator. The parameters of each function are stored in
non-volatile memory, and are not lost even if power is turned off.
F-functions:
These parameters can always be changed and are used for
internal settings.
CF-functions:
If you accept a certificated approval of the weighing instrument,
the CAL cover must be sealed. Therefore, accepting this approval,
the parameters of the CF-function can not be changed.
6.1. Changing the Function Settings
To enter the function settings, do either of the following.
1 When the display is off, press the ON/OFF key while pressing the +/- key.
2 When in the weighing mode, press both the F1 and F2 keys at the same time.
When you are in the function setting, F00 will be displayed.
Operating Item
Step 1 Select an item using the following keys.
key....... To select a digit.
key....... To select a value.
ENTER key . To display a parameter of the
selected item.
Proceed to step 2.
ESC key ...... To end the function setting and
enter the weighing mode.
CAL key ...... To switch between F-functions
and CF-functions.
Operating Parameter
Step 2 Select a parameter using the following keys.
key....... To select a digit or a sub item
(Type 2 or Type 3).
key....... To select a value or condition
ENTER key . To store a parameter and proceed to
step 1.
ESC key ...... To proceed to step 1 without
changing the parameter.
Display off
Press the ON/OFF key to turn the display off. This stores the changes.
6.
Functions
+/-
F 2
ENTER
F 1
ESC
Weighing
Weighing
ZERO
TARE
ZERO
TARE
F 2
ENTER
F 2
ENTER
F 1
ESC