ANALOGUE SYSTEMS RS-INTEGRATOR
123
Calibrate keyboard
This option allows you to
calibrate the RS290 so that, in
Sample mode, you can play the
sample from an "x" V/Oct
keyboard and have it track
correctly across a wide range.
To calibrate:
Apply a CV of 0v to the
ASSIGN/SAMPLE
PITCH
input, select "Apply 0V to
Sample pitch input" and then
press SELECT.
Next, apply a CV of 3V to the
same input (on a 1V/Oct
keyboard play a note three
octaves higher than before),
select "Apply 3V to Sample pitch
input", and then press SELECT.
The RS290 is now calibrated.
Apply 0V to assign
then press Edit
Calibrate keyboard
(press "EDIT")
Apply 3V to assign
then press Edit
Vx.x dd.mm.yy
Show version
(press "EDIT")
Show version
Display the version of the
operating system loaded.
Are you sure?
NO
Yes
Upgrade firmware
(press "EDIT")
Upgrade firmware
This option allows you to
upgrade the firmware that lies at
the heart of the RS290.
If you answer "Yes", the device
will show:
Flash programmer
Waiting for data...
If you are unable to present the
new software to the MIDI Input
on the RS295 Delay Expander,
the RS290 will lock up.
DO NOT WORRY.
Switch off the RS290, wait a few
seconds, and switch on again. It
will then function as before.