SAMPLE PITCH
Allows you to play back the sample at various pitches. If you have calibrated the 0V - 3V keyboard
scale correctly (see Common Menus / Special Options) you will be able to play the sample in
conventional fashion. You may also input non-keyboard control voltages for special effects.
Inputs
•
SIGNAL IN
Accepts audio signals in the range
±
3V. Signals in excess of 6V p-p will cause clipping.
•
F/B RETURN
Not used.
•
SAMPLE START CV
Accepts control voltages in the range -5V to +5V. The incoming voltage is added to that determined
by the SAMPLE START knob immediately above it.
•
SAMPLE END CV
Accepts control voltages in the range -5V to +5V. The incoming voltage is added to that determined
by the SAMPLE END knob immediately above it.
•
SAMPLE PITCH CV
Accepts control voltages in the range -5V to +5V. The incoming voltage is added to that determined
by the SAMPLE PITCH knob immediately above it.
•
TRIG1
Apply pulses in the range +1.5V to 20V to this input for use as a clock or LFO 'sync' reset.
•
TRIG2
Apply pulses in the range +1.5V to 20V to this input for use as a clock or LFO 'sync' reset.
Outputs
•
OUT L
Outputs a signal in the range
±
2.25V. Signals in excess of 4.5V p-p may be clipped.
•
OUT R / F/B SEND
Outputs a 50/50 mix of the existing sample (if played) and the signal presented to the SIGNAL
IN input.
Indicators
•
LEVEL (Signal IN & Signal OUT)
These offer visual feed back regarding the signal level at input and output.
- LED off
very low signal level
- LED green/amber
optimum signal level
- LED red