COM PORT VERIFICATION 

Installing the latest Firmware revision, as well as operating the 
ADXRS450 Evaluation GUI will require that the user know the 
communications port which has been assigned to the ISEB 
main board.  With the ISEB main board connected to the PC, 
the user should perform the following steps to determine the 
assigned COM port number: 
For Windows Vista: 

1.

 

From the start menu, right click on “Computer” and 
select “Properties” 
a.

 

This should open the window shown in  Figure 9 

2.

 

Underneath the “Tasks” heading, select “Device 
Manager” 
a.

 

Windows Vista may request that the user allow 
access to this panel, and Administrative privileges 
may be required. 

b.

 

The window shown in XYZ should now open 

3.

 

Expand the “Ports (COM & LTP)” menu item 
a.

 

The “ADI Inertial Sensor Evaluation System” 
should be listed with an assigned COM port 
number in parenthesis. 

4.

 

Note this value for future use 

 

Figure 5: Computer Properties 

 

Figure 6: Device Manager, showing the COM Port number 

For Windows XP/2000: 

1.

 

From the Start Menu, right click on “My Computer” 
and select “Properties”. 

2.

 

Click on the “Hardware” tab of the “System 
Properties” window as shown in Figure 11. 

3.

 

Select “Device Manager” to look-up the assigned 
COM port of the ISEB hardware 

a.

 

The Device Manager window should be 
similar to that presented in Figure 10 

 

Figure 7: System Properties 

 

 

Содержание ADXRS450

Страница 1: ...hamber for temperature or humidity testing Separating the boards mitigates corruption of data due to the temperature and humidity effects of other components The ISEB is a universal main board and is...

Страница 2: ...ion 4 Updating Repairing the ISEB Firmware 5 Inertial Sensor Evaluation System Graphical User Interface 8 Getting Started 8 View and Record Data 9 Temperature Test 10 Noise and Root Allan Variance 11...

Страница 3: ...leted the user can now connect the ISEB main board to the computer via the included USB cable Once connected if the previously installed drivers are not automatically associated with the device then t...

Страница 4: ...e Manager a Windows Vista may request that the user allow access to this panel and Administrative privileges may be required b The window shown in XYZ should now open 3 Expand the Ports COM LTP menu i...

Страница 5: ...COM port is selected click OK to accept the changes and go back to the main screen Figure 9 Selecting the Correct COM Port for the Downloader When the ISEB is connected the correct firmware is selecte...

Страница 6: ...s Figure 6 These directories can be changed by the user if desired however most installations can proceed with the default values Click Next 2 License Agreement Once the installation directories have...

Страница 7: ...o generate the device s required high voltage supply For more information on using alternate high voltage supplies refer to the ADXRS450 datasheet as well as the Alternate External High Voltage Supply...

Страница 8: ...OM port Refer to the PC s Device Manager under the Ports COM LTP submenu in order to determine which COM port has been assigned to the ADI Inertial Sensor Evaluation System Select this COM port from t...

Страница 9: ...software packages However the record functionality can be performed indefinitely if desired by the user Secondary information which is transmitted along with the plotted signals is graphically repres...

Страница 10: ...ew and Record panel allowed Data is again streamed to a file to allow for an indefinite length for data recording Before recording the data on this panel if the user wishes to adjust for any null offs...

Страница 11: ...t be run at least overnight during which time care should be taken to ensure that the device is in a temperature stable and disturbance free environment Any rotational rate input into the gyroscope ca...

Страница 12: ...intended application voltage To record the data from this panel ensure that the Record Bias Run Data box is checked before clicking the View Turn on Bias Stability button The user will be prompted to...

Страница 13: ...timings such that this specification is observed then it can be useful to know the behavior of the device from the moment power is applied By sending a series of Sensor Data Requests immediately after...

Страница 14: ...by the evaluation GUI The software must perform an initial calibration step in order to accurately calculate the angle of rotation 3 Once the null calibration is performed slowly rotate the satellite...

Страница 15: ...d with the high voltage supply the proper current is sourced to the ADXRS450 The supply requirements are described in detail in the ADXRS450 datasheet In short the main requirement for the external hi...

Страница 16: ...7 HEADER PINOUT Figure 26 ISEB 20 Pin Header Pinout ESD CAUTION 1 S1 2 3 S2 4 5 S3 6 7 S4 8 CS2 9 VS2 10 VS1 11 12 ST1 13 ST2 14 SCL1 15 SDA1 16 CLK 17 MOSI 18 MISO 19 CS3 20 CS4 P1 3 3V CS2 VS2 VS1 S...

Страница 17: ...or use of evaluation boards Information furnished by Analog Devices is believed to be accurate and reliable However no responsibility is assumed by Analog Devices for its use nor for any infringements...

Отзывы: