ADXL180
Rev. 0 | Page 52 of 56
MD[1:0]
Table 55. Phase 2 (Device Data) Transmission Mode Select
Codes
MD1 MD0 Name Definition
0
0
Mode 0
ADIFX mode device data
0 1 Mode
1
Range data only (range selection
limited)
1
0
Mode 2
8-bit coded device data
1
1
Mode 3
10-bit coded device data
Table 56. Phase 2 (Device Data) Transmission Mode Select
Codes
MD1 MD0 Data
0 0 Device
OK
0 1 Range
1 0 Delimiter
1 1 Device
OK
Table 57. MD Settings and Device Data Ranges with SVD and AZE Settings (Replication of Table 23)
Mode
(Device
Data)
MD1 MD0 SVD
Data Range
0: ADIFX
(All Configuration Data, Serial Number And Manufacturer ID)
0 0 0 0 Full
0 0 0 1 Reduced
0 0 1 0 Configuration
error
0 0 1 1 Configuration
error
1: Range Data Only
3
(Limited Range Selection)
0 1 0 0 Full
0 1 0 1 Reduced
0 1 1 0 Reduced
0 1 1 1 Reduced
2: 8-Bit Coded Device Data
(UD[7:0], Serial Number And Range)
1 0 0 0 Full
1 0 0 1 Reduced
1 0 1 0 Reduced
1 0 1 1 Reduced
3: 10-Bit Coded Device Data
(UD[7:0], Serial Number And Range)
1 1 0 0 Full
1 1 0 1 Reduced
1 1 1 0 Reduced
1 1 1 1 Reduced
1
SVD is the state vector disable configuration bit.
2
AZE is the auto-zero enable configuration bit.
3
If Phase 2 Mode 0, Mode 1, or Mode 2 is selected, the device data is 8-bit data. If the 10-bit data mode is selected in combination with Phase 2 Mode 0, Mode 1, or Mode
2, the 8-bit device data is left justified in the 10-bit data field. The two LSBs are held at zero (see Table 24).
4
The 10-bit device data mode (Phase 2 Mode 3) is incompatible with the 8-bit data mode (the DAT bit is set to 1). The device transmits a configuration error code if
Phase 2 Mode 3 is selected and the DAT bit is set to 1. No sensor data is transmitted.