UG-710
ADP1055-EVALZ User Guide
GUI 55S SETTINGS FILE
Copy the contents below into a text file and rename it with using an extension of .55s. Load this file in the GUI using
the Load settings
from file
option. Ensure that the last line of the .55s file does not have a carriage return.
Reg(1 h) = 80h - OPERATION
Reg(2 h) = 1Fh - ON_OFF_CONFIG
Reg(10 h) = 00h - WRITE_PROTECT
Reg(1B h) = 00780079007A007B007D007E007C0080h - SMBALERT_MASK
Reg(20 h) = 15h - VOUT_MODE
Reg(21 h) = 6000h - VOUT_COMMAND
Reg(22 h) = 0068h - VOUT_TRIM
Reg(23 h) = 0000h - VOUT_CAL_OFFSET
Reg(24 h) = 999Ah - VOUT_MAX
Reg(27 h) = 8000h - VOUT_TRANSITION_RATE
Reg(28 h) = 8000h - VOUT_DROOP
Reg(29 h) = 9AA7h - VOUT_SCALE_LOOP
Reg(2A h) = 9AA6h - VOUT_SCALE_MONITOR
Reg(33 h) = EBE8h - FREQUENCY_SWITCH
Reg(35 h) = E800h - VIN_ON
Reg(36 h) = E800h - VIN_OFF
Reg(37 h) = 0000h - INTERLEAVE
Reg(38 h) = B266h - IOUT_CAL_GAIN
Reg(39 h) = 8000h - IOUT_CAL_OFFSET
Reg(40 h) = 6C00h - VOUT_OV_FAULT_LIMIT
Reg(41 h) = FCh - VOUT_OV_FAULT_RESPONSE
Reg(42 h) = 6800h - VOUT_OV_WARN_LIMIT
Reg(43 h) = 4A65h - VOUT_UV_WARN_LIMIT
Reg(44 h) = 4800h - VOUT_UV_FAULT_LIMIT
Reg(45 h) = 3Ah - VOUT_UV_FAULT_RESPONSE
Reg(46 h) = E991h - IOUT_OC_FAULT_LIMIT
Reg(47 h) = FCh - IOUT_OC_FAULT_RESPONSE
Reg(48 h) = 0000h - IOUT_OC_LV_FAULT_LIMIT
Reg(49 h) = 00h - IOUT_OC_LV_FAULT_RESPONSE
Reg(4A h) = E971h - IOUT_OC_WARN_LIMIT
Reg(4B h) = E800h - IOUT_UC_FAULT_LIMIT
Reg(4C h) = B8h - IOUT_UC_FAULT_RESPONSE
Reg(4F h) = F1B8h - OT_FAULT_LIMIT
Reg(50 h) = FFh - OT_FAULT_RESPONSE
Reg(51 h) = F17Dh - OT_WARN_LIMIT
Reg(55 h) = EA1Ch - VIN_OV_FAULT_LIMIT
Reg(56 h) = 3Ch - VIN_OV_FAULT_RESPONSE
Reg(59 h) = E908h - VIN_UV_FAULT_LIMIT
Reg(5A h) = 3Ah - VIN_UV_FAULT_RESPONSE
Reg(5B h) = D1E0h - IIN_OC_FAULT_LIMIT
Reg(5C h) = FCh - IIN_OC_FAULT_RESPONSE
Reg(5E h) = 0000h - POWER_GOOD_ON
Reg(5F h) = 0000h - POWER_GOOD_OFF
Rev. B | Page 26 of 43