UG-710
ADP1055-EVALZ User Guide
Rev. B | Page 18 of 43
12
38
6-
05
5
Figure 56. IOUT_OC_FAULT
PSU is Set to Enter Constant Current Mode at 27 A. Fault Response Set to
Wait for a Debounce of 5 Seconds, Shutdown, and Retry Indefinitely.
Green Trace: Output Voltage
Yellow Trace: Load Current
1
23
8
6-
05
6
Figure 57. Constant Current Mode in a Load Resistor
Green Trace: Output Voltage
Yellow Trace: Load Current
12386-
057
Figure 58. Additional Settings in IOUT Window
In th
e Additional Settings
bar, the cycle by cycle protection
(over current and reverse current) can be set. Also, the constant
current averaging rate and the slew rate can be selected.
POUT WINDOW
The threshold limit for over load power can be set in this
window. The settings can be changed in a simple drag-and-drop
fashion. Changes take place immediately and are stored in
the RAM of the IC, but need to be saved to EEPROM for
permanent storage.
1
238
6-
0
58
Figure 59. POUT Window
TEMPERATURE WINDOW
In the
Temperature
window, the threshold for overtemperature
protection (OTP) and the low temperature threshold can be set.
The settings can be changed in a simple drag-and-drop fashion.
Changes take place immediately and are stored in the RAM of
the IC, but need to be saved to EEPROM for permanent storage.
1
2386-
059
Figure 60. Temperature Window