To connect one of the Remote Panels to an AutoPatch Switcher,
see
page 2-2.
Power must be applied to each panel separately
.
To apply power to linked Remote Panels,
use a transformer for each
panel or wire each panel separately into a centralized power source.
If using AutoPatch wall transformers, see the instructions on page 2-3.
If using a different transformer or a centralized power source, note that
the acceptable power for each controller using the left connector is
7 to 12 volt DC with at least 500 mA. Acceptable power for using the
right connector is 5 volt DC with at least 500 mA. See the transformer or
power source documentation for wiring information.
Note:
If experiencing difficulties, insert a 120 ohm resistor in the
outer contacts of the Comm Link on the last remote of a large daisy
chain and tighten the screws. If problems persist, call AutoAssist (see
Technical Support
on page 1-4.)