The following table lists the pinouts, signals, and pairing associated with the Ethernet connector.
FIG. 19 diagrams the RJ-45 pinouts and signals for the Ethernet RJ-45 connector and cable.
The NXD-700Vi panel can have up to two USB-capable input devices connected for use on its different
firmware and TPD4 panel pages. These input devices can consist of a keyboard or mouse.
1.
Insert the input device USB connectors into the appropriate USB connector on the panel.
2.
Press the on-screen
Reboot
button from the Protected Setup page to save any changes and restart
the panel.
3.
After the panel splash-screen disappears:
If a USB mouse has been connected, a mouse cursor appears on the panel screen and its
location corresponds to the mouse cursor position sent by the external USB mouse.
If a USB keyboard has been connected, only on-screen keyboards and keypads will reflect any
external keystrokes sent from the external USB keyboard.
Pin
Signals
Connections Pairing
Color
1
TX +
1 --------- 1
1 --------- 2
Orange-White
2
TX -
2 --------- 2
Orange
3
RX +
3 --------- 3
3 --------- 6
Green-White
4
no connection
4 --------- 4
Blue
5
no connection
5 --------- 5
4 --------- 5
Blue-White
6
RX -
6 --------- 6
Green
7
no connection
7 --------- 7
7 --------- 8
Brown-White
8
no connection
8 --------- 8
Brown
FIG. 19
RJ-45 wiring diagram
USB-connected input devices are not detected and recognized by the panel until
power is cycled to the unit.
A mini-USB connection is only detected after it is installed onto an active
panel. Connection to a previously powered panel, allows the PC to detect the
panel and assign an appropriate USB driver.
1 2 3
4 5 6 7 8
1 2 3
4 5 6 7 8