AMX Modero NXD-700Vi Скачать руководство пользователя страница 1

O p e r a t i o n / R e f e r e n c e   G u i d e

T o u ch   P a n e l s

Modero

®

 NXD-700Vi

G4 Touch Panels

7” Modero Widescreen Video Touch Panels

with Full Duplex Intercom

L as t   R e vi s ed :   1 / 2 2 / 20 0 9

Содержание Modero NXD-700Vi

Страница 1: ...Operation Reference Guide Touch Panels Modero NXD 700Vi G4 Touch Panels 7 Modero Widescreen Video Touch Panels with Full Duplex Intercom Last Revised 1 22 2009...

Страница 2: ...whichever is greater Products that are returned and exhibit signs of damage or unauthorized use will be processed under the Non Warranty Repair Policy AMX will continue to provide Warranty Repair Serv...

Страница 3: ...LIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WITH REGARD TO THE AMX SOFTWARE THIS LIM ITED WARRANTY GIVES LICENSEE SPECIFIC LEGAL RIGHTS Any supplements or updates to the AM...

Страница 4: ...wever there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by...

Страница 5: ...g NXD Outer Housing 9 Step 2 Install the new Compact Flash Memory card 10 Step 3 Close and Resecure the NXD Panel Enclosure 11 Installation 13 Installing the No Button Trim Ring 13 Installing the Butt...

Страница 6: ...to a target WAP200G 43 Step 3 Choose a Master Connection Mode 43 USB 43 Prepare your PC for USB communication with the panel 44 Configure the panel for USB communication 44 Configure a Virtual NetLin...

Страница 7: ...P LEAP Settings 88 EAP FAST Settings 90 EAP PEAP Settings 92 EAP TTLS Settings 94 EAP TLS Settings 96 Client certificate configuration 97 Calibration Page 99 G4 Web Control Page 100 Sensor Setup 102 M...

Страница 8: ...20 Setting Intercom Auto Answer 120 Advanced Setup 121 Allowing a panel to be monitored 121 Allowing a panel to monitor 122 Naming a panel 122 Sample Intercom Page 123 Answering an incoming call 125 C...

Страница 9: ...0 URL Resources 191 Special escape sequences 191 Appendix B Wireless Technology 193 Overview of Wireless Technology 193 Terminology 194 EAP Authentication 197 EAP characteristics 197 EAP communication...

Страница 10: ......

Страница 11: ...video and audio with overlay graphics for applications with demanding visual requirements Key features common to both panels include NXD 700Vi panels are based on the latest display technology and sup...

Страница 12: ...can be accomplished through these panels The wireless solution includes an NXA WC80211GCF internal Wi Fi card FG2255 07 that allows the NXD 700Vi to communicate with a NetLinx Master via a standard 8...

Страница 13: ...MB SDRAM 128 MB Compact Flash upgradeable to 1 GB factory programmed Weight stand alone NXD 700Vi 4 12 lbs 1 87 kg Certifications FCC Part 15 Class B andCE IEC60950 Panel LCD Parameters Aspect ratio 1...

Страница 14: ...aker Single 2 watt speaker LEDs 2 blue LEDs support On and Off Both the LEDs and pushbuttons are only available when using the default Button Trim Ring on the NXD panel Buttons 2 programmable pushbutt...

Страница 15: ...set up to 1 65535 Address port range 1 100 Operating Storage Environment Operating Temperature 0 C 32 F to 40 C 104 F Operating Humidity 20 85 RH Storage Temperature 20 C 4 F to 60 C 140 F Storage Hum...

Страница 16: ...SH CARD FG2116 74 NXA 700CF1G 1 G COMPACT FLASH CARD FG2116 75 It is recommended that firmware KIT files only be transferred over a direct USB or Ethernet connection and only when the panel is connect...

Страница 17: ...n of video data and audio to Modero touch panels located up to 200 feet 60 96 m from the AVB box This unit accepts either Composite or S Video from standard video devices This breakout box can be moun...

Страница 18: ...ouch panels over CAT5 cable up to 200 ft 60 9 m Availability This unit is included with CV5 CV7 CV10 NXD 700Vi NXD 1000V i and 1200V Series Kit configurations Front Components 2 pin 3 5 mm Phoenix con...

Страница 19: ...o and from the breakout box FIG 5 Sample wiring configuration on video capable panels using this breakout box FIG 6 Sample wiring configuration using non video capable Modero panels NXD T Video capabl...

Страница 20: ...nced and GND or unbalanced and GND audio signal can be connected to this output Video In BNCs Feeds either Composite S Video Luma or S Video Chroma signals into the NXA AVB ETHERNET This feed is then...

Страница 21: ...al to the signal ground Professional audio equipment will often use balanced audio inputs and outputs usually on 3 pin XLR connectors A balanced audio signal consists of a pair of wires carrying the a...

Страница 22: ...d audio input FIG 9 use all three audio terminals and GND then connect the terminal to the live signal the terminal to the return signal and the GND terminal to the ground signal FIG 9 Balanced OUT GN...

Страница 23: ...11B CF Wireless Interface Card WIC This unit is certified and available for use in the United States FCC Canada IC Europe CE and Japan TELEC 802 11b Wireless Interface Card Specifications Dimensions H...

Страница 24: ...grade available at www amx com Operating Channels 11 Channels USA Canada 13 Channels Europe 14 Channels Japan 4 Channels France Operating Environment Temperature 0 C 70 C non operating and 15 80 C sto...

Страница 25: ...he CF metal cover plate is not present over the wireless card slot on a NXD 700Vi NXD 1000Vi CV7 or CV10 panel you can use the adhesive tape to secure the terminal antenna to the surface of the new ca...

Страница 26: ...460 mA Standby 240 mA Radio Data Rate 802 11g compliant 1 2 5 5 11 DSSS CCK 6 9 12 18 24 36 48 and 54 OFDM Mbps data rates Radio Technology Using 802 11b communication DSSS Direct Sequence Spread Spec...

Страница 27: ...9 01 03 NXD CV7 FG2258 02 NXT CV7 FG2258 01 Included Accessories Double sided adhesive tape Mounting Template cutout 62 2255 04 NXA WC80211GCF Installation Guide Two Alcohol cleaning pads Wireless CF...

Страница 28: ......

Страница 29: ...card in both panel types involves opening the panel enclosure outer housing to access the internal circuit board removing the existing card replacing it and then resecuring the panel enclosure as desc...

Страница 30: ......

Страница 31: ...side of the unit FIG 3 This step helps prevent scratching of the LCD 3 Firmly press down on both connector overlay release latches located in front of the connectors Pressing down releases the connect...

Страница 32: ...side of the existing card and gently pry the card out of the slot FIG 6 Repeat this process on the opposite card removal groove This alternating action causes the card to wiggle away from the on boar...

Страница 33: ...connector overlay back into the connector opening by inserting the top of the overlay into the connector opening in an upwards direction 4 Align the connectors to their respective locations and secure...

Страница 34: ......

Страница 35: ...by gently tugging it outwards until the entire Faceplate comes away from the panel 2 Turn the Faceplate over to expose the inside surface and view the Trim Ring latches FIG 7 3 In a single motion pres...

Страница 36: ...0Vi unit Make sure to align the Microphone Light and PIR Motion sensor locations on the main unit to their respective openings on the Faceplate assembly The outer No Button Trim Ring is secured to the...

Страница 37: ...into their corresponding openings on the outer surface of the internal Faceplate FIG 10 9 Firmly press down around the Button Trim Ring until all of the latches are securely inserted into their openi...

Страница 38: ...cut out the surface slightly smaller than what is outlined in the installation drawings so that you can make any necessary cutout adjustments The wiring knockouts on the left side will be used for th...

Страница 39: ...wall and optional NXA RK7 Rack Mount Kit Installing the NXD panel within a Conduit Box The conduit box must be mounted prior to continuing this section Refer to the procedures in the Pre Wall Installa...

Страница 40: ...faceplate bezel 9 Reconnect the terminal RJ 45 Ethernet USB and any optional audio video wiring to their respective locations outside the conduit box on either the NXA AVB ETHERNET Breakout Box Ether...

Страница 41: ...he surface opening Leave enough slack in the wiring to accommodate any re positioning of the panel 5 Connect all data and power wiring connectors to their corresponding locations along the left side o...

Страница 42: ...rim Ring assembly A in FIG 14 back onto the main NXD unit B in FIG 14 Make sure to align the Microphone Light and PIR Motion sensor locations to their respective openings on the front faceplate bezel...

Страница 43: ...n drawings so that you can make any necessary cutout adjustments 1 Prepare the area by removing any screws or nails from the surface before beginning the cutout process 2 Cut out the surface for the N...

Страница 44: ...ead screwdriver until the unit is secure and flush against the wall FIG 16 10 Place the Faceplate Trim Ring assembly A in FIG 16 back onto the main unit B in FIG 16 Make sure to align the Microphone L...

Страница 45: ...repetition of the installation 5 Disconnect the terminal end of the power cable from the connected power supply 6 Carefully insert the NXD 700Vi panel into the NXA RK7 7 Secure the panel to the NXA R...

Страница 46: ...s and damage the connector Wiring a power connection To use the 2 pin 3 5 mm mini Phoenix connector with a 12 VDC compliant power supply the incoming PWR and GND wires from the external source must be...

Страница 47: ...ls Audio Video RJ 45 Pinout Information Pin Wire Color Function Polarity 1 Orange White Right Audio In 2 Orange Right Audio In 3 Green White Video In 4 Blue Mic Out 5 White Blue Mic Out 6 Green Video...

Страница 48: ...ears on the panel screen and its location corresponds to the mouse cursor position sent by the external USB mouse If a USB keyboard has been connected only on screen keyboards and keypads will reflect...

Страница 49: ...replaced by the Initial Panel Page FIG 20 1 Press and hold the grey Front Setup Access button FIG 21 for 6 seconds to pass over the Setup page and access the Calibration setup page FIG 22 2 Press the...

Страница 50: ...second on screen message that appears On screen crosshairs used for calibration of the touch device after the calibration process is completed If the calibration was improperly set and you cannot retu...

Страница 51: ...If Calibration Is Not Working Cycling power to the panel should provide a baseline calibration for the particular touch panel Re calibrate the panel...

Страница 52: ......

Страница 53: ...rotected Setup page Enter 1988 the default password and press Done to proceed Before commencing verify you are using the latest NetLinx Master and Modero panel firmware Verify you are using the latest...

Страница 54: ...the pre installed wireless CF card inside the panel The panels allow users to connect to a wireless network through their use of the pre installed AMX 802 11g wireless interface card to communicate wi...

Страница 55: ...communication is set within the IP Settings section of this page FIG 26 2 Toggle the DHCP Static field from the IP Settings section until the choice cycles to DHCP This action causes all fields in th...

Страница 56: ...Secondary DNS field 9 Press the Domain field to open a Keyboard enter the resolvable domain Address this is provided by your System Administrator and equates to a unique Internet name for the panel a...

Страница 57: ...detected for 10 scans in a row it is then removed from the screen In this way a user can walk around a building and see access points come and go as they move in and out of range 3 Sort the informati...

Страница 58: ...y mode when a WEP Access Point is selected and then connected to the user is then redirected back to the Static WEP security screen where the SSID field is already filled out and the user is only requ...

Страница 59: ...pressing the Connect button Manually entering the SSID information into their appropriate fields by following steps 7 thru 9 3 From within the Wireless Security section press the Open Clear Text butt...

Страница 60: ...ion process 8 Verify the fields in the IP Settings section have been properly configured Refer to Step 1 Configure the Panel s Wireless IP Settings section on page 33 for detailed information 9 Press...

Страница 61: ...cal keys for the same Passphrase The generators used on WAPs will not produce the same key as the Modero generator even if you use the same Passphrase For this reason we recommend FIRST creating the C...

Страница 62: ...oblems associated with connection to a WAP arise because the SSID was not entered properly You must maintain the same case when entering this information ABC is not the same as Abc The alpha numeric s...

Страница 63: ...keyboard If you are wanting to have your target WAP other than an NXA WAP200G generate the Current Key Do not press the Generate button and continue with Step 13 This keyboard allows you to enter a P...

Страница 64: ...ning Current Key and Authentication fields are greyed out and cannot be altered by the user 12 Verify the fields within the IP Settings section have been properly configured Refer to Step 1 Configure...

Страница 65: ...de between it and your master In the Protected Setup page 1 Select System Settings 2 Select Type to toggle between the Master Connection Types USB and Ethernet A USB connection is a direct connection...

Страница 66: ...the blue Type field from the Master Connection section until the choice cycles to USB Refer to the System Settings Page section on page 77 for information about the fields on this page 5 Press the Bac...

Страница 67: ...this situation the PC takes on the functions of a Master via a Virtual NetLinx Master This connection is made by either using the PC s Ethernet Address via TCP IP using a known PC s IP Address as the...

Страница 68: ...w to view the devices on the Virtual System 10 Right click on Empty Device Tree System and select Refresh System to re populate the list The panel will not appear as a device below the virtual system...

Страница 69: ...s from the Main menu to open the Master Communication Settings dialog FIG 40 Connection Modes Mode Description Procedures Auto The device connects to the first master that responds This setting requir...

Страница 70: ...and click OK to open the command DOS prompt From the C command line enter ipconfig to display the IP Address of the PC This information is entered into the Master IP URL field on the panel 9 Click OK...

Страница 71: ...the Master IP URL field to open a Keyboard and enter the IP Address of the PC used as the Virtual Master 18 Click Done to accept the new value and return to the System Settings page 19 Do not alter t...

Страница 72: ...Control page FIG 42 6 Press the Enable Enabled button until it toggles to Enabled light blue color 7 The Network Interface Select field is read only and displays the method of communication to the web...

Страница 73: ...ontrol password 14 Press the Web Control Port field to open the Web Port Number keypad 15 Within the keypad enter a unique numeric value to be assigned to the port the VNC Web Server is running on The...

Страница 74: ...required for access or configuration Both HTTP and HTTPS Ports are enabled by default via the Manage System Server page If the Master has been previously configured for secured communication click OK...

Страница 75: ...ethod of communication you are using it can be found in either the Wired Ethernet System Settings IP Settings section within the IP Address field Wireless Wireless Settings IP Settings section within...

Страница 76: ...the panel and begin the session A confirmation message appears stating Please wait Initial screen loading The secondary window then becomes populated with the same G4 page being displayed on the targ...

Страница 77: ...ter the installation of the USB driver has been completed confirm the proper installation of the large Type A USB connector to the PC s USB port and restart your machine 2 After the panel powers up pr...

Страница 78: ...green 8 Navigate back to the System Settings page 1 Launch NetLinx Studio 2 x default location is Start Programs AMX Control Disc NetLinx Studio 2 NetLinx Studio 2 2 Select Settings Master Communicat...

Страница 79: ...the panel to mini USB on the panel is configured properly using the steps outlined in the previous two sections 2 With the panel already configured for USB communication and the Virtual Master setup w...

Страница 80: ...Click the Reboot Device checkbox This causes the touch panel to reboot after the firmware update process is complete The reboot of the panel can take up 30 seconds after the firmware process has finis...

Страница 81: ...2 x default location is Start Programs AMX Control Disc NetLinx Studio 2 NetLinx Studio 2 3 Select Settings Master Communication Settings from the Main menu to open the Master Communication Settings...

Страница 82: ...gs 17 Click Reboot from the Tools Reboot the Master Controller dialog and wait for the System Master to reboot The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation Wai...

Страница 83: ...Center Firmware Files and from within the Modero section of the web page locate your Modero panel 5 Click on the desired Kit file link and after you ve accepted the Licensing Agreement verify you hav...

Страница 84: ...begin the transfer The file transfer progress is indicated on the bottom right of the dialog FIG 52 11 Click Close after the panel reboots to return to the main program 12 Right click the associated S...

Страница 85: ...rmation FIG 53 Press to access the Protected Setup page for panel calibration and to access security release passwords and connection settings Press to access the Information menu and select either Pr...

Страница 86: ...panel s connection status regardless of what page is currently active When a connection is established the message displayed is either Connected via Ethernet or Connected via USB If no connection can...

Страница 87: ...UP DN buttons to increase decrease the time the panel can remain inactive before it flips to the preset page Range 0 240 minutes Use this button to set the timeout value to zero and disable the inact...

Страница 88: ...con if the panel has established a connection with a currently secured target Master requiring a username and password File Name Displays the name of the TPDesign4 project file downloaded to the panel...

Страница 89: ...d number information of the TPD4 software used to create the project file Creation Date Displays the project creation date Revision Date Displays the last revision date for the project Last Save Date...

Страница 90: ...o panel Maximum available screen width on a NXD 700Vi Modero panel is 800 pixels Screen Height Displays the pixel height being used to display the incoming video signal on the Modero panel Maximum ava...

Страница 91: ...he previous page Connection Status icon The icon in the upper right corner of each Setup page provides a constant visual indication of current connection status Note a Lock appears on the icon if the...

Страница 92: ...0 59 Second range 0 59 FIG 59 Volume Page Elements Back Saves the changes and returns you to the previously active touch panel page Connection Status icon This visual display of the connection status...

Страница 93: ...indicates the current sound level The Mute button mutes the volume Default 50 Analog Line In Level Allows you to adjust the current Line In volume level being received from the communicating breakout...

Страница 94: ...ling rates for WAV files are Video Adjustment Page The Video Setup page FIG 60 accessed by pressing the Video Adjustment button on the Setup page sets the Video properties of the incoming video signal...

Страница 95: ...Settings button saves any changes made to this page Video Settings The Black White button toggles the Black White display mode Default Off The Sharpness button toggles the Interpolate Sharpness featur...

Страница 96: ...and select either Panel Logs Panel Statistics or Press to access the Calibration page where you can calibrate the panel display and control of the panel via a web enabled PC running a VNC client Conne...

Страница 97: ...rious touch panel features The Function Show button enables the display of the channel port and channel code in the top left corner of the button the level port and level code in the bottom left corne...

Страница 98: ...delay timer that does not enable the YES button for 5 seconds This delay provides an additional amount of time for the user to confirm their decision The Remove User Pages button allows you remove al...

Страница 99: ...s visual display of the connection status allows the user to have a current visual update of the panel s connection status regardless of what page is currently active A Lock only appears on the icon i...

Страница 100: ...Ethernet connection to the panel Choices are Auto 10 Half Duplex 10 Full Duplex 100 Half Duplex or 100 Full Duplex MAC Address Displays a read only field that is factory set by AMX for the built in Et...

Страница 101: ...the NetLinx Master ETHERNET Only disabled when USB is selected Master Port Number Allows you to enter the port number used with the NetLinx Master Default value is 1319 ETHERNET Only disabled when US...

Страница 102: ...f detectable Signal Strength None Poor Fair Good Very Good and Excellent MAC Address Unique identification of the transmitting Access Point Refer to the Using the Site Survey tool section on page 34 f...

Страница 103: ...on opens the EAP TLS Settings page FIG 75 on page 96 EAP TLS security is designed for wireless environments where it is necessary to securely transmit data over a wireless network by adding an additio...

Страница 104: ...time None Poor Fair Good Very Good and Excellent Even when link quality is at its lowest you still have a connection and the ability to transmit and receive data even if at lower speeds Note Link Qua...

Страница 105: ...Open Clear Text Settings Press the Open Clear Text button to open the Open Clear Text Settings page FIG 67 FIG 67 802 11g wireless card...

Страница 106: ...ar Text Settings SSID Service Set Identifier Opens an on screen keyboard to enter the SSID name used on the target WAP The SSID is a unique name used by the WAP and is assigned to all panels on that n...

Страница 107: ...ws you to enter a pass phrase The panel then automatically generates four WEP keys compatible only with Modero panels Enter these WEP keys into the target WAP When working with multiple panels WEP Key...

Страница 108: ...o the Wireless Access Point Keys may also be examined by touching the key buttons and noting the keyboard initialization text Use the on screen keyboard s Clear button to erase stored key information...

Страница 109: ...guring a Wireless Network Access section on page 33 for details on these security options Refer to the Using the Site Survey tool section on page 34 for more information on using this tool SSID Servic...

Страница 110: ...not use client panel or server RADIUS certificates and is therefore one of the least secure EAP security methods but can be utilized successfully by implementing sufficiently complex passwords EAP LE...

Страница 111: ...n access to a secured workstation Typ ically this is in the form of a username such as jdoe amx com Password Opens an on screen keyboard Enter the network password string specified for the user entere...

Страница 112: ...FAST Settings Press the EAP FAST button to open the EAP FAST Settings dialog FIG 72 EAP FAST Flexible Authentication via Secure Tunneling security was designed for wireless environments where securit...

Страница 113: ...as the identity but that does not repre sent a real user This information is used as a fictitious name which might be seen by sniffer programs during the initial connection and setup process between t...

Страница 114: ...ersions of the PEAP protocol supported by panel s DeviceScape Wireless Client PEAPv0 PEAPv1 PEAP uses inner authentication mechanisms supported by the DeviceScape Wireless Client the most common of wh...

Страница 115: ...tation Typ ically this is in the form of a username such as jdoe amx com Password Opens an on screen keyboard Enter the network password string specified for the user entered within the Identity field...

Страница 116: ...allowing it access to the network This validation is done by tunneling a connection through the WAP and directly between the panel and the Radius server Once the client is identified and then validat...

Страница 117: ...ard Enter the network password string specified for the user entered within the Identity field used by the panel to identify itself to an Authentication RADIUS Server Note This information is similar...

Страница 118: ...by the WAP before the panel is permit ted to join the network The SSID is case sensitive and must not exceed 32 characters Make sure this setting is the same for all points in your wireless network NX...

Страница 119: ...entity of the client panel Refer to the Client certificate configuration section for information regarding Client Certificates and their parameters Private Key When pressed the panel displays an on sc...

Страница 120: ...by the different certificate fields used on the configuration screens PEAP TTLS and TLS The following table outlines the firmware fields and their supported certificate types PKCS12 files are frequen...

Страница 121: ...een message Calibration successful is the second on screen message that appears On screen crosshairs used for calibration of the touch device after the calibration process is completed If the calibrat...

Страница 122: ...le Enabled button allows you to toggle between the two G4 activation settings Enable deactivates G4 Web Control on the panel Enabled activates G4 Web Control on the panel Network Interface Select Disp...

Страница 123: ...inx Security application G4 Web Control Timeout Sets the length of time in minutes that the panel can remain idle no cursor movements before the G4 Web Control session is terminated Minimum value 0 mi...

Страница 124: ...light level The DIM mode Min Level can never exceed the DIM Mode Max Level Back Saves the changes and returns you to the previously active touch panel page Connection Status icon This visual display...

Страница 125: ...aph can never exceed that of the Dim Mode Max Level Dim Mode Minimum Brightness Allows you to alter the sensitivity of the Modero panel light sensor Toggle the Enable Enabled button to either active i...

Страница 126: ...e drop in the lighting level being detected by the panel in response to your movements Wake Panel On Motion Sense The Wake Panel Sensitivity relates to the sensitivity of the motion sensor to detect m...

Страница 127: ...a normal working environment The Other Settings button provides a menu to select the Image Caching page Password Setup page or SIP Settings page Select any option to access its page The minimum lower...

Страница 128: ...ly be moved to Flash since it is typically faster to retrieve images on Flash than across a network although it is slower than RAM cache Note that since static images are already stored on Flash they...

Страница 129: ...as requested that the image was found in the cache of cache misses the number of times an image was requested that the image could not be found in the cache and the image had to either be loaded from...

Страница 130: ...increase or reduce the amount of Flash memory used the maximum amount of flash that can be allocated for caching is 75 of available flash In the Protected Setup page 1 Press the Cache button in the P...

Страница 131: ...device sends strings to control the device and receives commands from the UI module or telnet sessions Refer to the documentation supplied with the Duet Module for more details Back Saves the changes...

Страница 132: ...roxy server However point to point SIP will still be enabled allowing for existing intercom functionality Connection State This option displays whether you are connected to the proxy server Proxy Addr...

Страница 133: ...n on page 111 the Panel Statistics Page section on page 112 or the Connection Utility Page section on page 114 Select any of the options to access that page The options on the Panel Logs page allow yo...

Страница 134: ...ges Ethernet connection statistics and Wireless connection statistics FIG 82 Back Saves all changes and returns to the previous page Connection Status icon The icon in the upper right corner of each S...

Страница 135: ...l it is the protocol they use to communicate to each other Total Received The total ICSP messages received by the panel Processed The total ICSP messages processed by the panel Dropped The total ICSP...

Страница 136: ...resh button 1 Press the Tools button in the Protected Setup Navigation Buttons section This opens the Tools menu 2 Within the Tools menu press the Panel Statistics button 3 Push the Clear button 4 Con...

Страница 137: ...panel is currently communicating with the target WAP Note Data rates for 802 11b communication are 1 2 5 5 and 11 Mbps Link Quality Displays the quality of the link from the wireless NIC to the Wirele...

Страница 138: ...el throughout your wireless network and changes within the utility The Connection Information notes the IP of the connected master and the IP of your panel The Wireless Information indicates the curre...

Страница 139: ...certificate that is installed in a panel so that the RADIUS server can be validated before the panel tries to connect to it The field name associated with this file is Certificate Authority If a serv...

Страница 140: ......

Страница 141: ...Download the module for the intercom panel from www amx com and include it in your NetLinx project file For searching purposes the module manufacturer is AMX and the model is Intercom The setup page...

Страница 142: ...r call exceeds your session timeout the panel provides you with a popup FIG 90 to extend the session 3 Press Exit when you are finished 1 Select the Setup button on your intercom page 2 Press the butt...

Страница 143: ...ther panels intercom call directory pages 1 Select the Setup button on your intercom page 2 On the intercom setup page press Advanced Setup This launches the password numeric keypad 3 Enter the passwo...

Страница 144: ...rmission to be monitored your panel provides the popup in FIG 93 5 Press Back to return to the intercom setup pages 6 Press Exit when you are finished 1 Select the Setup button on your intercom page 2...

Страница 145: ...ame of the panel as it appears in other intercom directories See Naming a panel section on page 122 0 265 2 Page All Pages all connected intercom panels 1 6 3 Place Call Initiates an intercom call to...

Страница 146: ...panel enact privacy against the panel and monitor the panel 1 5 1 5 12 Call Panel Display only indicates the panel is currently in a call 1 21 13 Call Panel Display only indicates the panel is curren...

Страница 147: ...el Display only indicates the panel is being monitored by another panel 1 32 26 Monitor Panel Display only indicates the panel is being monitored by another panel 1 35 27 Intercom Microphone Level A B...

Страница 148: ...standard page flip to Advanced Setup Exit Setup Navigates the intercom panel to the intercom directory page This requires a standard page flip to the intercom directory Advanced Setup Name Description...

Страница 149: ...iable Text range 1 4000 per address port Button States Range 1 256 0 All states for General buttons 1 Off state and 2 On state Level Range 1 600 Default level value 0 255 can be set up to 1 65535 Addr...

Страница 150: ...rs Name of the page the popup is displayed On reset flag 1 Enable reset flag 0 Disable reset flag Example SEND_COMMAND Panel PDR Popup1 1 Popup1 will return to its default location when turned On PHE...

Страница 151: ...ay as the Hide Popup command in TPDesign4 Syntax PPF popup page name page name Variable popup page name 1 50 ASCII characters Name of the popup page page name 1 50 ASCII characters Name of the page th...

Страница 152: ...anel PPM Popup1 Modal Sets the popup page Popup1 to Modal SEND_COMMAND Panel PPM Popup1 1 Sets the popup page Popup1 to Modal PPN Activate a specific popup page to launch on either a specified page or...

Страница 153: ...the effect will begin at Syntax PSP popup page name x coordinate y coordinate Variable popup page name 1 50 ASCII characters Name of the page the popup is displayed On Example SEND_COMMAND Panel PSP...

Страница 154: ...the Toggle Popup command in TPDesign4 Syntax PPOG popup page name page name Variable popup page name 1 50 ASCII characters Name of the popup page page name 1 50 ASCII characters Name of the page the p...

Страница 155: ...rk Red 95 0 0 06 Very Light Orange 255 128 0 07 Light Orange 223 112 0 08 Orange 191 96 0 09 Medium Orange 159 80 0 10 Dark Orange 127 64 0 11 Very Dark Orange 95 48 0 12 Very Light Yellow 255 255 0 1...

Страница 156: ...0 127 53 Very Dark Blue 0 0 95 54 Very Light Purple 128 0 255 55 Light Purple 112 0 223 56 Purple 96 0 191 57 Medium Purple 80 0 159 58 Dark Purple 64 0 127 59 Very Dark Purple 48 0 95 60 Very Light...

Страница 157: ...0 0 0 255 TRANSPARENT 99 53 99 Default Font Styles and ID Numbers Font ID Font type Size Font ID Font type Size 1 Courier New 9 19 Arial 9 2 Courier New 12 20 Arial 10 3 Courier New 18 21 Arial 12 4 C...

Страница 158: ...3 Circle 15 7 Single line 24 27 Neon inactive S 8 Double line 40 41 Diamond 55 9 Quad line TPD4 Border Styles by Name No Border styles No Border styles 1 None 22 Circle 155 2 AMX Elite L 23 Circle 165...

Страница 159: ...62 Help Down 104 Menu Top Rounded 65 63 Neon Active L 105 Menu Top Rounded 75 64 Neon Active S 106 Menu Top Rounded 85 65 Neon Inactive L 107 Menu Top Rounded 95 66 Neon Inactive S 108 Menu Top Round...

Страница 160: ...unded 125 147 Menu Left Rounded 115 130 Menu Right Rounded 135 148 Menu Left Rounded 125 131 Menu Right Rounded 145 149 Menu Left Rounded 135 132 Menu Right Rounded 155 150 Menu Left Rounded 145 133 M...

Страница 161: ...ith page name Main Page BAT Append non unicode text Syntax BAT vt addr range button states range new text Variable variable text address range 1 4000 button states range 1 256 for multi state buttons...

Страница 162: ...range 1 4000 button states range 1 256 for multi state buttons 0 All states for General buttons 1 Off state and 2 On state color value Refer to theRGB Values for all 88 Basic Colors table on page 133...

Страница 163: ...Text Icon and Image Example 2 SEND_COMMAND Panel BDO 1 0 12345 Sets all states of a button back to its default drawing order BFB Set the feedback type of the button ONLY works on General type buttons...

Страница 164: ...pied as a separate command The codes section represents what attributes will be copied All codes are 2 char pairs that can be separated by comma space percent or just ran together Syntax BMC vt addr r...

Страница 165: ...20 29 32 xx Set the font See theDefault Font Styles and ID Numbers table on page 135 F font 01 08 10 11 20 29 32 xx Set the font See theDefault Font Styles and ID Numbers table on page 135 MI mask im...

Страница 166: ...mand on page 151 for more information VI video ON OFF Set the Video either ON value 1 or OFF value 0 OT feedback type Set the Feedback Output Type to one of the following None Channel Invert ON Always...

Страница 167: ...dr range max length Variable variable text address range 1 4000 max length 2000 0 no max length Example SEND_COMMAND Panel BML 500 20 Sets the maximum length of the text area input button to 20 charac...

Страница 168: ...port 1 65535 Example SEND_COMMAND Panel BNT 973 5000 Sets the TakeNote button network port to 5000 BOP Set the button opacity The button opacity can be specified as a decimal between 0 255 where zero...

Страница 169: ...04 510 515 The border style is available through the TPDesign4 border style drop down list Refer to theTPD4 Border Styles by Name table on page 136 for more information BOS Set the button to display e...

Страница 170: ...variable text address can be in focus at a time Syntax BSF vt addr range selection value Variable variable text address range 1 4000 selection value Unselect 0 and select 1 Example SEND_COMMAND Panel...

Страница 171: ...tion of the button BVN Set the network name for the specified address Syntax BVN vt addr range network name Variable variable text address range 1 4000 network name 1 50 ASCII characters Example SEND_...

Страница 172: ...dy exists Syntax DFP vt addr range actions page name Variable variable text address range 1 4000 actions Stan dardPage Flip to standard page Prev iousPage Flip to previous page Show Popup Show Popup p...

Страница 173: ...Generate Programmer s Report Text Only Format Readme txt GDI Change the bargraph drag increment Syntax GDI vt addr range bargraph drag increment Variable variable text address range 1 4000 bargraph d...

Страница 174: ...ress range 1 4000 bargraph ramp down time In 1 10th of a second intervals Example SEND_COMMAND Panel GRD 500 200 Changes the bargraph ramp down time to 20 seconds GRU Change the bargraph ramp up time...

Страница 175: ...e variable text address range 1 4000 bargraph slider name See table below Example SEND_COMMAND Panel GSN 500 Ball Changes the bargraph slider name or the Joystick cursor name to Ball Bargraph Slider N...

Страница 176: ...d 2 On state new text alignment Value of 1 9 corresponds to the following locations Example SEND_COMMAND Panel JSB 500 504 510 515 1 2 1 Sets the off on state picture alignment to upper left corner fo...

Страница 177: ...o the upper left corner for those buttons with variable text ranges of 500 504 510 515 MBT Set the Mouse Button mode On for the virtual PC Syntax MBT pass data Variable pass data 0 None 1 Left 2 Right...

Страница 178: ...vt addr range button states range text effect name Variable variable text address range 1 4000 button states range 1 256 for multi state buttons 0 All states for General buttons 1 Off state and 2 On s...

Страница 179: ...dow 3 Hard Drop Shadow 3 Glow X Medium Drop Shadow 4 Hard Drop Shadow 4 Outline S Medium Drop Shadow 5 Hard Drop Shadow 5 Outline M Medium Drop Shadow 6 Hard Drop Shadow 6 Outline L Medium Drop Shadow...

Страница 180: ...EVENT TP 529 1011 ON state Border Color CUSTOM_EVENT TP 529 1012 ON state Fill Color CUSTOM_EVENT TP 529 1013 ON state Text Color CUSTOM_EVENT TP 529 1014 Border Name CUSTOM_EVENT TP 529 1015 Opacity...

Страница 181: ...or multi state buttons 0 All states for General buttons 1 Off state and 2 On state custom event type 1011 Flag zero Value1 Button state number Value2 Actual length of string should be 9 Value3 Zero Te...

Страница 182: ...ster would be ButtonGet Id 529 Type 1012 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT FF8000FF TEXT LENGTH 9 BCT Get the current text color Syntax BCT vt addr range button states range Variable variable tex...

Страница 183: ...p information The result sent to the Master would be ButtonGet Id 529 Type 1002 Flag 0 VALUE1 1 VALUE2 9 VALUE3 0 TEXT Buggs png TEXT LENGTH 9 BOP Get the overall button opacity Syntax BOP vt addr ran...

Страница 184: ...Master would be ButtonGet Id 529 Type 1014 Flag 0 VALUE1 1 VALUE2 22 VALUE3 0 TEXT Double Bevel Raised L TEXT LENGTH 22 BWW Get the current word wrap flag status Syntax BWW vt addr range button states...

Страница 185: ...the Master would be ButtonGet Id 529 Type 1007 Flag 0 VALUE1 1 VALUE2 72 VALUE3 0 TEXT TEXT LENGTH 0 ICO Get the current icon index Syntax ICO vt addr range button states range Variable variable text...

Страница 186: ...to the Master would be ButtonGet Id 529 Type 1005 Flag 0 VALUE1 1 VALUE2 5 VALUE3 0 TEXT TEXT LENGTH 0 JSI Get the current icon justification Syntax JSI vt addr range button states range Variable vari...

Страница 187: ...1004 Flag 0 VALUE1 1 VALUE2 1 VALUE3 0 TEXT TEXT LENGTH 0 TEC Get the current text effect color Syntax TEC vt addr range button states range Variable variable text address range 1 4000 button states r...

Страница 188: ...ALUE2 18 VALUE3 0 TEXT Hard Drop Shadow 3 TEXT LENGTH 18 TXT Get the current text information Syntax TXT vt addr range button states range optional index Variable variable text address range 1 4000 bu...

Страница 189: ...he Keyboard and initializes the text string Texas with prompt text Enter State AKEYB Pop up the keyboard icon and initialize the text string to that specified Keyboard string is set to null on power u...

Страница 190: ...Keypad Remove keyboard or keypad that was displayed using AKEYB AKEYP PKEYP AKB AKP PKP EKP or TKP commands Syntax AKR Example SEND COMMAND Panel AKR Removes the Keyboard Keypad BEEP Output a beep Sy...

Страница 191: ...ializes the text string 123456789 in PKP Present a private keypad Pops up the keypad icon and initializes the text string to that specified Keypad displays a instead of the numbers typed The Prompt Te...

Страница 192: ...the startup string to STARTUPNOW SWK Change Wakeup string Syntax SWK string Variables string name of wakeup string Example SEND COMMAND Panel SWK WAKEUPNOW Changes the wakeup string to WAKEUPNOW TKP...

Страница 193: ...other panel Syntax TPAGEON Example SEND COMMAND Panel TPAGEON Turns On page tracking TPAGEOFF Turn Off page tracking Syntax TPAGEOFF Example SEND COMMAND Panel TPAGEOFF Turns Off page tracking VKB Pop...

Страница 194: ...to the Master via the Send Output String mechanism This process sends a virtual keystroke command VKS to the Master Example 2 SEND COMMAND Panel KPS 0 Disables the keyboard passthru to the Master The...

Страница 195: ...TPS 0 1 Variable 1 Creates a transparent connection between the touch input serial port and the program port This is useful for connecting a PC to the program port and controlling touch input on that...

Страница 196: ...F4 135 87 F5 136 88 F6 137 89 F7 138 8A F8 139 8B F9 140 8C F10 141 8D F11 142 8E F12 143 8F Num Lock 144 90 Caps Lock 145 91 Insert 146 92 Delete 147 93 Home 148 94 End 149 95 Page Up 150 96 Page Dow...

Страница 197: ...e 0x0003 Purge both non volatile and RAM image caches Example SEND_COMMAND Panel CPR 3 Purges all images from both primary RAM cache and backup Flash cache CFS Modifies the size of the backup image Fl...

Страница 198: ...index 1 2 Hours 2 8 Hours 3 1 Day 4 2 Days 5 5 Days 0 NEVER Example SEND_COMMAND Panel CEX 4 Changes the default expiration time to 2 Days DLD Set the disable cradle LED flag Syntax DLD 0 1 Variables...

Страница 199: ...l PWD 1 Main Sets the page flip password on Password Level 1 to Main RPP Reset the protected password RPP resets the protected password to its default 1988 Syntax RPP Example SEND COMMAND Panel RPP Re...

Страница 200: ...regardless of current view This command can be used by programmers to prefetch images that will be needed soon Syntax RFRP resource name Variable resource name 1 50 ASCII characters Example SEND_COMM...

Страница 201: ...hing a resource causes the button displaying that resource to refresh also The default value is 0 only download the resource once Full path to the location of the file or program that will return the...

Страница 202: ...ata packets will actually flow until the intercom modify command is sent to the panel Syntax SEND_COMMAND DEV ICS IP TX UDP port RX UDP port initial mode Variables IP IP Address of panel to connect wi...

Страница 203: ...connection id used for all future commands related to this call The connection id will be 0 or 1 Syntax PHN INCOMING caller number caller name connection id timestamp Variable caller number The phone...

Страница 204: ...mber of new messages old message count The number of old messages new urgent message count The number of new messages marked urgent old urgent message count The number of old messages marked urgent Ex...

Страница 205: ...le SEND_COMMAND Panel PHN HANGUP 1 PHN HOLD Places the call on hold Syntax PHN HOLD connection id Variable connection id The identifying number of the connection Example SEND_COMMAND Panel PHN HOLD 1...

Страница 206: ...uthentication Example SEND_COMMAND Panel PHN SETUP DOMAIN asterisk PHN SETUP ENABLE Registers a new user Once the configuration has been updated the ENABLE command should be run to re register the new...

Страница 207: ...ress for the STUN server Example SEND_COMMAND Panel PHN SETUP STUNADDR 192 168 223 111 PHN SETUP USERNAME Sets the user name for authentication with the proxy server Syntax PHN SETUP USERNAME username...

Страница 208: ......

Страница 209: ...below Bargraph Text Code Inputs Code Bargraph Multi State Bargraph P Display the current percentage of the bargraph derived from the Adjusted Level Value as it falls between the Range Values Display t...

Страница 210: ...number of characters in a text area Suggest proper format with fixed characters Right to Left Required or Optional Change Force a Case Create multiple logical fields Specify range of characters number...

Страница 211: ...To define a literal character enter any character other than those shown in the above table including spaces and symbols A back slash causes the character that follows it to be displayed as the litera...

Страница 212: ...ld the overflow value is added to the previous field on the chain if the overflow character was specified In the above example if the overflow flag was set the first example will place the 1 into the...

Страница 213: ...native port could be specified as http www amx com 8080 company info home asp Special escape sequences The system has only a limited knowledge of URL formats in that it transparently passes the URL in...

Страница 214: ......

Страница 215: ...via the wireless network The wired network connection always takes priority As an example Imagine a panel connected to two networks A B A is the wired network and B is the wireless network If the Mas...

Страница 216: ...as Top Secret The AES cipher is the first cipher protecting Top Secret information available to the general public CERTIFICATES CA A certificate can have many forms but at the most basic level a certi...

Страница 217: ...dentified weaknesses in this scheme WEP was superseded by Wi Fi Protected Access WPA and then by the full IEEE 802 11i standard also known as WPA2 WPA Wi Fi Protected Access WPA and WPA2 is a class of...

Страница 218: ...n WPA2 implements the full standard but will not work with some older network cards Both provide good security with two significant issues either WPA or WPA2 must be enabled and chosen in preference t...

Страница 219: ...ver 2003 Juniper Odyssey once called Funk Odyssey Meetinghouse AEGIS Server DeviceScape RADIUS Server Cisco Secure ACS The following table outlines the differences among the various EAP Methods from m...

Страница 220: ...to the RADIUS server providing its identity and specifying which EAP type it wants to use If the server does not support the EAP type then it sends a failure message back to the WAP which will then d...

Страница 221: ...ciated error messages if any The Certificate Upload Utility recognizes the following certificate file types CER Certificate File DER Distinguished Encoding Rules PEM Privacy Enhanced Mail PFX Normal W...

Страница 222: ...D after changing the communication from Ethernet to USB until the panel is rebooted Once the panel restarts the connection turns a dark green until connected to an active USB cable 5 Press the Back bu...

Страница 223: ...If using an Ethernet connection skip to step 8 6 For a USB connection select the 10 XX XX 1 IP Address which corresponds to the virtual IP Address assigned to the USB connection port on the computer 7...

Страница 224: ...Send entry with the Type column selected as a group by clicking on the Check All radio box located at the top of the device IP Address listing 13 When you are ready to send the certificate file to th...

Страница 225: ......

Страница 226: ......

Страница 227: ...tion to a target panel you are prompted with a G4 Authentication dialog which asks you to enter the assigned password for the panel before gaining access If you are ever prompted with a VNC Server dia...

Страница 228: ...negotiate a DHCP Address and try again My panel is not showing up in the Virtual Master s System list of connected devices If you a Virtual Master has already connected to the target panel the G4 devi...

Страница 229: ...the panel Calibration is not working After the Modero touch panel has been updated with a new firmware kit downloaded to the panel through NetLinx Studio the calibration could need to be reset Cyclin...

Страница 230: ...ommunication Settings Settings for TCP IP uncheck the Automatically Ping the Master Controller to ensure availability The pinging is to determine if the Master is available and to reply with a connect...

Страница 231: ...ng a panel file or firmware to a G4 device the panel behaves strangely Symptoms include Having to repeat the download Inability to make further downloads to the panel May get directory errors graphics...

Страница 232: ......

Страница 233: ......

Страница 234: ...egistered trademarks of AMX AMX reserves the right to alter specifications without notice at any time It s Your World Take Control 3000 RESEARCH DRIVE RICHARDSON TX 75082 USA 800 222 0193 469 624 8000...