PAGE PASSWORD
displays a keypad. When you use the PAGE edit menu,
PROTCT PG FLIP option, you will use the password you enter here to gain access to
the protected page. If you forget the password, you win not be able to enter the
protected page. Be sure to save the number in a safe place. The default password is
1988.
SYMBOL EDITOR
displays a matrix of 30 squares used to display existing symbols.
Touching one of the squares displays a symbol editing screen. Create up to 30 of
your own symbols and save them. The symbols you create are selected when you
touch the VARIABLE SYMBOLS button in the keyboard characters window
.
SERIAL MASTER MODE
is used to select the Touch Panel port as the AXCESS
program port. Doing this allows you to change AXCESS programs using the Touch
Panel as a remote port. Connect your computer to the DB-9 connector. Set the Touch
Panel data rate to 19.2K baud maximum.
AUTO ASSIGN
turns the AUTO ASSIGN function on or off. The button stays lighted
when the function is on. You choose AUTO ASSIGN when you want unique
function codes assigned automatically from the BUTTON edit menu, ATTRIBUTES
option.
POWER UP PAGE
displays a page menu when this key
i
s touched. Use the up and
down arrows to select the page name you want to see displayed when power is
applied. If you choose NONE, the last page displayed will appear when power is
applied.
EL TIMER MESSAGE
displays a selection window. Select one of the four options
that will be displayed on the screen during the Touch Panel screen-saver time-out
period.
PAGE TRACKING
turns the PAGE TRACKING function on or off. The button stays
lit when the function is on. You choose page tracking when you want to have all
Touch Panels track together. Code is required in the AXCESS system to do this.
MOUSE
displays a page of mouse pointer options. You can turn the mouse feature
on or off, and change the shape of the mouse pointer.
BOTH MODE, RS-232 BUS
Data Bus Selection
selects one of three data bus
odes. Consecutively touch this button selects. You can have AXlink (bus) only, RS-
232 only, or both.
POWER UP MESSAGE
displays the keyboard. Enter a message that will be sent
from the Touch Panel RS-232 port when it is fast powered up. You can use the
message to
wake up
equipment attached to your control system.
Содержание Electroluminescent LCD Touch Panels
Страница 8: ...4 Introduction Electroluminescent Touch Panels...
Страница 22: ...18 Operation Electroluminescent Touch Panels...
Страница 26: ...22 Specifications Electroluminescent Touch Panels...
Страница 28: ...24 Technical Support Electroluminescent Touch Panels...
Страница 37: ...Electroluminescent Touch Panels Appendix Page and Function Finders 33...