Installation
7
5.5" Color Passive Mini-Touch Panels
14.
Remove the backing from the adhesive tape strips; press the engraved overlay onto the
faceplate. Once attached to the faceplate, the security screws cannot be replaced without
removing the overlay.
15.
Reconnect the AXlink wiring to the Central Controller. The touch panel beeps on power-up.
Rack-mount panel (AXM-MCP/PB)
1.
Thread the incoming AXlink wiring through the opening in the equipment rack.
2.
Disconnect the AXlink connector from the Central Controller.
3.
Insert the touch panel into the equipment rack. Line up the top-left and bottom-right screw
holes and tighten the #6-32 screws. Then, tighten the bottom-left and top-right screws.
4.
Connect the AXlink connector to the touch panel. Refer to the
Wiring the Mini-Touch
Panels
section on page 8 for more information. The touch panel will beep on power-up.
FIG. 5
Decor-style (AXD) and CB-MTP cutout dimensions for plasterboard