![Amsco C Series Скачать руководство пользователя страница 137](http://html1.mh-extra.com/html/amsco/c-series/c-series_operators-manual_2936189137.webp)
9-17
Troubleshooting
Operator Manual
P129394-176
Screen with Operator Instructions
9.3.10 Emergency
Stop Switch Pressed
The emergency stop
switch has been
pressed.
Screen with Service Instructions
STATUS . . ALARM!
273
EMERGENCY STOP SWITCH PRESSED
CHAMBER: 300.0 F 0.0 psig
STERILIZER WILL:
•
STOP
OPERAT0R INSTRUCTIONS:
1. SILENCE ALARM
2. CORRECT THE CAUSE FOR THE EMERGENCY
STOP.
3. INSERT KEY AND TURN COUNTERCLOCKWISE
TO RESET THE EMERGENCY STOP SWITCH
4. WAIT FOR THE CYCLE TO ABORT
5. RESTART THE CYCLE
6. CALL SERVICE IF ALARM DOES NOT CLEAR
STATUS
SILENCE
ALARM
PAPER
FEED
SERVICE
HELP
STATUS . . ALARM!
274
. . . . .
EMERGENCY STOP SWITCH PRESSED
-> NO 120VQC POWER IS DETECTED ON I/O BOARD
#1.
CAUSES AND CORRECTIONS:
1. EMERGENCY STOP SWITCH PRESSED OF FAILED
OPEN
2. OPEN WIRING TO CONTROL (P37 CABLE)
3. OPEN IN CONTROL WIRING TO J14 ON
BACKPLANE
4. FAILED I/O BOARD #1
5. FAILED BACKPLANE