77
MSI/PLESSEY DECODER
ON
Enable reading MSI/Plessey bar codes.
OFF * Disable reading MSI/Plessey bar codes.
TWO CHECK DIGITS REQUIRED
ON
Two valid check digits are required for each label. The first check digit is
defined by option
2) below. The second check digit is always mod 10.
OFF * One valid check digit is required for each label. The check digit must be
mod 10.
FIRST CHECK DIGIT MOD 11
ON
The First Check Digit must be mod 11.
OFF * The First Check Digit must be mod 10.
SEND FIRST CHECK DIGIT
ON
Transmit the First Check Digit.
OFF * Do not transmit the First Check Digit.
SEND SECOND CHECK DIGIT
ON
Transmit the Second Check Digit.
OFF * Do not transmit the Second Check Digit.
ISBN PLESSEY
ON
Enable reading of Modified Plessey ISBN bar codes. Only eleven digit
ISBN bar codes will be read.
OFF* Do not read Modified Plessey ISBN bar codes.