Motor Control Connectors
Motor Speed (Tach) Connectors
Pin # Function
1 Motor Power
2 Motor Ground
Pin # Function
1 Tach Power
2 Tach Signal
3 Tach Ground
Note:
•
Electric motor or electric over hydraulic control is
possible
•
Terminated in Deutsch DT06-2S connector, contacts
rated to 13 amps, 16AWG wiring
•
Mating connector is Deutsch DT04-2P
Note:
•
Connector mates with Powell TBC. TBC (CAN
BUS terminating bias circuit) should only be installed
at the physical end of the CANBUS system.
•
Terminated in Metripack 12052848 connector (150
Series)
Meter Box Sensor Connectors
Low-Bin Level Sensor
Connectors
Pin # Function
1 Meter Power
2 Meter Signal
3 Meter Ground
Pin # Function
1 Bin Power
2 Bin Signal
3 Bin Ground
Note:
•
Independent feedback for up to 4 bin level sensors
(infrared, capacitive proximity)
•
Mates directly to Agtron bin level sensors, 3rd party
sensors may require additional wiring
•
Terminated in Deutsch DTM06-3S connector, con-
tacts rated to 7 amps, 20AWG wiring
•
Mating connector is Deutsch DTM04-3P
Note:
•
Independent feedback for up to 4 additional bin level
sensors (infrared, capacitive proximity)
•
Mates directly to Agtron bin level sensors, 3rd party
sensors may require additional wiring
•
Terminated in Deutsch DTM06-3S connector, con-
tacts rated to 7 amps, 20AWG wiring
•
Mating connector is Deutsch DTM04-3P