3.5 VALVE CLEARANCE
* Intake-0.10±0.02mm(cold),(0.003±0.005inches)
*Exhaust-0.15±0.02mm(cold),(0.005±0.007inches)
After the first 50 hours of operation, check the valve
clearance in the engine and adjust if necessary.
Important:
If feeling uncomfortable about doing this procedure or
the proper tools are not available, please take the generator to
the nearest service center to have the valve clearance adjusted.
This is a very important step to ensure longest life for the engine.
3.6 GENERAL
The generator should be started at least once every seven days
and be allowed to run at least 30 minutes. If this cannot be done
and the unit must be stored for more than 30 days, use the
following information as guide to prepare it for storage.
Never store engine with fuel in tank indoors
or in enclosed, poorly ventilated areas where fumes may
reach an open flame, spark or pilot light as on a furnace,
water heater, clothes dryer or other gas appliance.
3.7 LONG TERM STORAGE
It is important to prevent gum deposits from forming in essential
fuel system parts such as the carburetor, fuel hose or tank during
storage. Also , experience indicates that alcohol- blended fuels
(called gasohol, ethanol or methanol) can attract moisture, which
leads to separation and formation of acids during storage. Acidic
gas can damage the fuel system of an engine while in storage.
To avoid engine problems, the fuel system should be emptied
before storage of 30 days or longer, as follows.
*Remove all gasoline from the fuel tank.
Drain fuel into approved container outdoors,
away from open flame. Be sure engine is cool. Do not
smoke.
* Start and run engine until stops from lack of fuel.