2.2 CORD SETS AND CONNECTION PLUGS
2.2.1 120VAC, 20 AMP, DUPLEX RECEPTACLE.
This is a 120 volt outlet protected against overload by a 13.5 amp
push - to - reset circuit breaker 13.5 amps of current may
be drawn from each socket; however, total power drawn must be
kept within data plate ratings. Use only high quality, well insulated,
3-wire grounded cord sets rated for 125 volts at 20 amps (or
greater).
2.3 HOW TO USE THE GENERATOR
If there are any problems operating the generator, please call the
generator helpline at 1-888-545-7788
Using a generator indoors
WILL KILL YOU IN
MINUTES.
Exhaust contains carbon monoxide, a poison gas you
cannot see or smell.
NEVER use in the home, or in partly enclosed far from open
windows, doors, vents, and in an area that will not
accumulate deadly exhaust gas.
2.3.1 GROUNDING THE GENERATOR
The national electrical code requires that the frame and
external electrically conductive parts of this generator be
properly connected to an approved earth ground (figure
7).
local electrical codes may also require proper grounding of the
unit. For that purpose, connecting a no. 10 AWG (American wire
gauge) stranded copper wire to the grounding rod (electrode)
provides adequate protection against electrical shock. However,
local codes may vary widely.
Consult with a local electrician
for grounding requirements in the area.