IMPORTANT
: Do not overload the generator. Also, do not
overload individual panel receptacles. These outlets are
protected against overload with push-to-reset-type circuit
breakers. If amperage rating of any circuit breaker is exceeded,
that breaker opens and electrical output to that receptacle is lost.
Read “don’t overload the generator” carefully.
2.8 STOPPING THE ENGINE
*Shut off all loads, and then unplug the electrical loads from
generator panel receptacles. Never start or stop the engine with
electrical devices plugged in and turned on.
*Let engine run at no-load for several minutes to stabilize the
internal temperatures of engine and generator.
*Move ON/OFF switch to OFF position.
*Close fuel valve.
2.9 LOW OIL LEVEL SHUTDOWN SYSTEM
The engine is equipped with a low oil level sensor that shuts
down the engine automatically when the oil level drops below a
specified level. If the engine shuts down by itself and the fuel tank
has enough gasoline, check engine oil level.
2.9.1 SENSING LOW OIL LEVEL
If the system senses a low oil level during operation, the engine
shuts down. The engine will not run until the oil has been refilled
to the proper level
3.1 MAINTENANCE SCHEDULE
Follow the calendar intervals. Move frequent service is required
when operating in adverse conditions noted below.
Check oil level At each use
Change oil + *Every season
Check valve clearance ***Every season
Service air filter **Every season
Replace spark plug Every season
+Change oil after first 20 hours of operation, then every season.
*Change oil every month when operating under heavy load or in
19
19