23
Q. Install electrical system
Connect the power source on the data plate of power unit.
Note: 1. For the safety of operators, the power wiring must contact the floor well.
2. Pay attention to the direction of rotations when using three phase motors.
Single phase motor (See Fig. 34).
1.
Connecting the two power supply lines (
Active
L
and
Neutral
wire
N
) to terminals of AC
contactor marked
6#, 2#
respectively.
2.
Connecting the power supply earth wire to
G
on the motor.
3.
Connecting the Limit Switch: Removing the wire of connecting terminal
4#
on
control button and terminal
1#
on AC contactor firstly
(See Fig. 35)
, then
connecting wire
10#
of the limit switch with terminal
4#
of the control button and
connecting wire
9#
with terminal
A1
on AC contactor respectively
(See Fig. 36)
.
Motor Connecting Diagram
Fig. 34
9#
Remove this wire
before connecting
the Limit Switch
10#
Fig. 35
Fig. 36
Содержание HS-12
Страница 1: ...TWO POST LIFT Model HS 12 ...
Страница 2: ......
Страница 4: ...0 ...
Страница 6: ...2 Arm Swings View For Model HS 12 Fig 2 ...
Страница 12: ...8 D Install parts of extension columns See Fig 15 Fig 15 ...
Страница 20: ...16 J Install safety device See Fig 23 Fig 24 Fig 23 Powerside safety device Fig 24 Offside safety device ...
Страница 21: ...17 K Lift the carriages up by hand and make them be locked at the same level See Fig 25 Fig 25 ...
Страница 28: ...24 IV EXPLODED VIEW Model HS 12 Fig 37 Car in direction ...
Страница 29: ...25 Main Cylinder Secondary Cylinder Fig 38 Fig 39 ...
Страница 39: ...35 ...
Страница 40: ...36 AMGO HYDRAULIC CORPORATION Tel 803 505 6410 Fax 803 505 6410 1931 Jo Rogers Blvd Manning South Carolina USA ...