S-4000 LT
1-21
Revised 10/2004
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
OUTPUTS
To change the value of a parameter on the first line
, press
key and change by
key. To confirm
rm
the set values, press
key.
To change the value of a parameter on the second line
, press
key
ey
(2x) and change by
key. To confirm the set values, press
key.
y.
1.
Pulses
-
Pulses off
appears on the display. Press
key to activate the output 0 on the
control unit FX1 and
Pulses on
appears on the display.
2.
Servo
-
Servo off
appears on the display. Press
key to activate the output 2 on the
control unit FX1 and
Servo on
appears on the display.
3.
Clamps
-
Clamps off
appears on the display. When the
key is pressed, the clamp
feet are closed and the
Clamps on
appears on the display. Valve YV2 is tested by this
parameter.
Note:
The air supply is required for this parameter testing.
D - MACHINE CONTROLS
8.
Servo ready
-
Servo ready off
appears on the display (if not, press and release the Emergency
Stop button). Return to the main screen. The message „Motor not ready“ appears on
the display. Press and release the Emergency Stop button and press
button.
The main screen appears on the display. Press
key and then
key.
y.
Scroll down to find Servo ready parameter.
Servo ready on
appears on the display.
9.
Low air pressure
-
Low air pressure off
appears on the display. If the air pressure is lower than 0.5 MPa,
the message
Low air pressure on
appears on the display. The switch BQ 2 is tested
by this parameter.
10.
Optical Sensor
-
there
Optical Sensor Off
on the display. Suspend the ray on the sensor with hand.
Optical Sensor On
will show on the display — proper sensor function checking.