S-4000 LT
1-9
Revised 10/2004
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phone: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
3 . P OW E R A N D A I R C O N N E C T I O N
1.
The machine is equipped with a quick coupler
➍
required with connector for inner
∅
of the tube 10.
The connector for inner
∅
of the tube 8 is not supplied with
the machine, a customer has to order it. The manufacturer
recommends to use connector
➏
for customers who requires
to connect the tube with connector NPT.
If a customer needs to use a shut off valve
➊
, which allows
fast releasing of the air from the circuit, he must order it.
A variety of connectors
➋
can be used separately or in
combination to adapt to the available input supply hose. It
depends on type of the tube which is used by a customer.
These connectors are not included in the accessories. A
tubing clamp
➌
is provided.
N O T E :
Parts
➊
,
➋
,
➎
,
➏
are included in Extra Parts - see
3-42.
2.
After air connection check the set air pressure on the dial of the regulator. It should be in range
0.5 - 0.6 MPa. The green pointer
➐
indicates the lowest working air pressure 0.5 MPa, which is set
from the manufacturer on the regulator
➑
. If the air pressure is lower than 0.5 Mpa after connecting
the machine to the power supply, the red LED
➒
lights up on the regulator and „Low Pressure“
message appears on the control panel display. To adjust the working pressure, loosen the regulator
cap lock
➓
and turn the regulator cap clockwise to increase the pressure. Push the regulator cap
➓
down. The LED
is for setting the minimal operation air pressure.
3.
Power supply must be 208 to 230 volts 1 phase, 50 or 60 hertz. Receptacle plug must meet
requirements of IEC standard 364-4-41, its circuit breaker must be minimal 10A with characteristic
C according to the EN 60947-2 (or 16A with characteristic B). No other devices must not be connected
to the circuit breaker of the socker. The hand wheel
must turn counter clockwise.
The machine is equipped with a filters which contain capacitors which generate an high frequency
leakage current. In order to prevent nuisance tripping, residual current protection device must be
protected against these high frequency currents: this is the case for industrial residual current
device (example „S“ type).
B - MACHINE ASSEMBLY
Ê
Ë
Ì
Î
Ï
Í