Installation
4
BOSS Scoring Bowler Terminal Consoles
Installation, Operation, Service, and Parts Manual
400-286-003 Rev. New
!
5.
Route and attach J1 and J2 cables from the floor outlets to the bowler terminal board
located in the bowler terminal console.
6.
Ensure that the bowler terminal is mounted flush to the floor underneath. Insert and
tighten four 8mm x 75 mm hex head screw bolts (709-013-059) to base of bowler
terminal.
7.
Place the four plug buttons (248-001-509) on top of the base of the pedestal to cover
8mm x 75 mm hex head screw bolts (709-013-059).
8.
Set the switches on the bowler terminal board by using the switch configuration label
settings (286-001-074) located on the pedestal assembly (286-002-056). For proper
configuration, refer to the section called Switch Configuration Settings.
S
TANDARD
B
OWLER
T
ERMINAL
C
ONSOLE
(
WITH
I
NTERCOM
U
PGRADE
)
This section describes the procedures necessary to upgrade the standard bowler
terminal when the intercom feature has been purchased. You will be performing some
soldering tasks during this procedure so please have a soldering iron, solder, wire
strippers, wire cutters, and the basic knowledge for soldering devices. See Figure 2
and Figure 3 displays the necessary information to assist you in soldering the assembly.
1. Verify that the power to the unit is turned OFF at the main circuit breaker.
2. Open front cover on bowler terminal and remove four #4-40 hex nuts (843-121-002)
and faston tabs (760-022-262) from keyboard plate (286-002-037).
WARNING
Do NOT enter the bowler terminal until all power to the
unit is turned off at the main breaker box or serious injury
could result.