4-6 | Thermox WDG-V UOP IECEx/ATEX
Retrofitting the WDG-V UOP to WDG-IV UOP
These instructions require that each WDG-V UOP sensor is paired
with its own AMEVision as described in the Single Sensor Analyzer
Connection diagram.
Follow these instruction when retrofitting the WDG-IV UOP that uses
the Series 2000 controller to the WDG-V UOP using AMEVision and the
AMEVision display unit.
1. Disconnect customer wiring and conduit entries from the existing
WDG-IV UOP electronics enclosure.
2. Series 2000 Controller:
Mark all wires with their corresponding Series
2000 circuit board terminal designation (see Figure 4-3).
3. Disconnect wiring and conduit entries from the existing Series 2000
control unit.
4. Remove the existing
WDG-IV UOP Sensor
from the process flange
and the Series 2000 controller from the installation.
5. Install the new
WDG-V UOP Analyzer
and
AMEVision controller
as described in the standard installation instructions included in the
manual.
6. Using the existing wiring and conduit entries remaining from the
WDG-IV UOP Analyzer and Series 2000 Controller, reconnect as
shown in Figure 4-3.
7. Match up the numbered terminals on the terminal strip to the previ-
ous Series 2000 circuit board terminal designations (Step 2) that should
be marked on the wires in the AMEVision.
Содержание Thermox WDG-V UOP
Страница 34: ...2 6 Thermox WDG V UOP IECEx ATEX This page intentionally left blank...
Страница 65: ...AMEVision Display Installation Guide 4 5 Customer I O Connections...
Страница 68: ...4 8 Thermox WDG V UOP IECEx ATEX This page intentionally left blank...
Страница 80: ...5 12 Thermox WDG V UOP IECEx ATEX This page intentionally left blank...
Страница 85: ...Service and Parts 6 5 Cell Clips Cell Housing Washer Cell O Ring Hex Nut Figure 6 2 Cell replacement...
Страница 87: ...Service and Parts 6 7 Speed Clips Thermocouple Thermocoouple Figure 6 3 Thermocouple replacement...
Страница 91: ...Service and Parts 6 11 Box Heater Block Furnace Wires Heater Figure 6 6b Box Heater Replacement...
Страница 96: ...6 16 Thermox WDG V UOP IECEx ATEX This page intentionally left blank...